Owner manual
TECHNICAL DATA 7
31
OPTIBATCH 4011 C
www.krohne.com01/2012 - 4000868402 - MA OPTIBATCH R02 en
7.2 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local representative.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Measuring principle Coriolis mass flow
Application range Measurement of liquids in batching and filling machines
Measured values Mass
Calculated values Volume
Design
Basic System consists of a measuring sensor with integral converter to process
the output signal
Features Fully welded maintenance- free sensor with twin U-shaped measuring tube
Variants
VariantsVariants
Variants
Compact version Integral converter
Measuring accuracy
Mass
MassMass
Mass
Q
nom
x 0.1 ≤ Q ±0.15% of actual measured flow rate
Q < Q
nom
x 0.1 ±0.1% of actual measured flow rate + zero stability
Volume
VolumeVolume
Volume
Q
nom
x 0.1 ≤ Q ±0.2% of actual measured flow rate
Q < Q
nom
x 0.1 ±0.15% of actual measured flow rate + zero stability
Zero stability
Zero stabilityZero stability
Zero stability
Stainless Steel 0.005% of nominal flow
Repeatability (at reference condtions)
Repeatability (at reference condtions)Repeatability (at reference condtions)
Repeatability (at reference condtions)
Filling time Standard deviation
1.5 s < Filling time ≤ 3 s 0.13%
3 s < Filling time ≤ 5 s 0.07%
5 s < Filling time 0.04%
Reference conditions
Reference conditionsReference conditions
Reference conditions
Warm-up time 15 min
Product Water
Temperature +20°C / +68°F
Operating pressure 1 barg / 14.5 psig
Accreditation UKAS to EN17025
MA_OPTIBATCH_en_120302_4000868402_R02.book Page 31 Thursday, August 2, 2012 3:17 PM