User guide

INSTALLATION 2
17
OPTIFLEX 2200 C/F
www.krohne.com04/2013 - 4000861902 - AD IECEX OPTIFLEX2200 R02 en
Compact and Remote (Field) versions
EPL Da/Db, Db: Ex ia and Ex ia tb devices
EPL Dc: Ex ic devices
Maximum flange
temperature
Maximum ambient temperature
Ø2 mm / Ø0.08¨
single cable probe
(HT version)
Ø2 mm / Ø0.08¨
single cable probe
(other versions)
All other probe types
Compact
version
Remote
(Field)
version
Compact
version
Remote
(Field)
version
Compact
version
Remote
(Field)
version
[°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F]
+80 +176 +80 +176 +80 +176 +80 +176 +80 +176 +80 +176 +80 +176
+90 +194 +79 +174 +79 +174 +76 +169 +75 +167 +77 +170 +76 +169
+100 +212 +78 +172 +77 +170 +72 +161 +70 +158 +74 +165 +73 +163
+110 +230 +76 +169 +76 +169 +68 +154 +64 +147 +70 +158 +69 +156
+120 +248 +75 +167 +74 +165 +64 +147 +59 +138 +67 +152 +65 +149
+130 +266 +74 +165 +73 +163 +59 +138 +54 +129 +64 +147 +61 +142
+140 +284 +73 +163 +71 +160 +55 +131 +49 +120 +61 +142 +58 +136
+150 +302 +72 +161 +70 +158 +51 +124 +43 +109 +57 +134 +54 +129
+160 +320 +71 +160 +68 +154 - - - - - - - -
+170 +338 +69 +156 +67 +152 - - - - - - - -
+180 +356 +68 +154 +65 +149 - - - - - - - -
+190 +374 +67 +152 +64 +147 - - - - - - - -
+200 +392 +66 +151 +62 +144 - - - - - - - -
+210 +410 +65 +149 +61 +142 - - - - - - - -
+220 +428 +64 +147 +59 +138 - - - - - - - -
+230 +446 +62 +143 +58 +136 - - - - - - - -
+240 +464 +61 +142 +56 +133 - - - - - - - -
+250 +482 +60 +140 +55 +131 - - - - - - - -
+260 +500 +59 +138 +53 +127 - - - - - - - -
+270 +518 +58 +136 +52 +125 - - - - - - - -
+280 +536 +57 +134 +50 +122 - - - - - - - -
+290 +554 +55 +131 +49 +120 - - - - - - - -
+300 +572 +54 +129 +47 +116 - - - - - - - -