User guide

INSTALLATION 2
9
OPTIFLEX 4300 C
www.krohne.com02/2009 - 4000523601 - AD ATEX OPTIFLEX 4300 R01 en
Equipment category II 1 G (Ex ia devices only)
Equipment category II 1/2 G
Equipment category II 2 G: Ø2 mm/Ø0.08¨ single cable probe (HT, HP and HT/HP versions)
Temperature class Ambient temperature Flange temperature
[°C] [°F] [°C] [°F]
T6 -20+60 -4+140 -20+60°C -4+140
Temperature class Ambient temperature Flange temperature
[°C] [°F] [°C] [°F]
T6 -40+60 -40+140 -20+60°C -4+140
T5 -40+75 -40+167 -20+60°C -4+140
T4 -40+85 -40+185 -20+60°C -4+140
Temperature
class
Ambient temperature Flange temperature
Ø2 mm/Ø0.08¨ single cable
probe (HT version)
Ø2 mm/Ø0.08¨ single cable
probe (other versions)
[°C] [°F]
[°C] [°F] [°C] [°F]
T6 -40+60 -40+140 -40+60 -40+140 -50+60 1 -58+140 2
-40+56 -40+133 -40+52 -40+126 -50+85 1 -58+185 2
T5 -40+75 -40+167 -40+75 -40+167 -50+75 1 -58+167 2
-40+71 -40+160 -40+67 -40+153 -50+100 1 -58+212 2
T4 -40+85 -40+185 -40+85 -40+185 -50+85 1 -58+185 2
-40+80 -40+176 -40+77 -40+170 -50+110 1 -58+230 2
-40+77 -40+170 -40+70 -40+158 -50+135 1 -58+275 2
T3 -40+75 -40+165 -40+65 -40+149 -50+150 1 -58+302 2
-40+71 -40+160 - - -50+180 1 -58+356 2
-40+69 -40+157 - - -50+200 1 -58+392 2
T2 -40+62 -40+144 - - -50+250 1 -58+482 2
-40+55 -40+131 - - -50...+300 1 -58+572 2
1 -50°C, if an EPDM gasket is used. -40°C, if a Viton® GLT gasket is used. -20°C, if a Kalrez® 6375 gasket is used.
2 -58°F, if an EPDM gasket is used. -40°F, if a Viton® GLT gasket is used. -4°F, if a Kalrez® 6375 gasket is used.
AD_ATEX_OPTIFLEX4300_en_090528_4000523601_R01_D5D.book Page 9 Thursday, May 28, 2009 6:00 PM