Manual

6 TECHNICAL DATA
32
OPTIMASS 2400
www.krohne.com 07/2014 - 4003533101- MA OPTIMASS 2400 R01 en
On site calibration
±0.5 kg/m
3
/ ±0.033 lbs/ft
3
Temperature
TemperatureTemperature
Temperature
Accuracy ±1°C / ±1.8°F
Operating conditions
Maximum flow rates
Maximum flow ratesMaximum flow rates
Maximum flow rates
S100 420000 kg/h / 14698 lbs/min
S150 900000 kg/h / 33804 lbs/min
S250 2300000 kg/h / 84510 lbs/min
Custody transfer flow rates (mass)
Custody transfer flow rates (mass)Custody transfer flow rates (mass)
Custody transfer flow rates (mass)
S100 11000...220000 kg/h / 404...8083 lbs/min
S150 25000...500000 kg/h / 919...18371 lbs/min
S250 60000...1200000 kg/h / 2205...44092 lbs/min
Custody transfer flow rates (volume)
Custody transfer flow rates (volume)Custody transfer flow rates (volume)
Custody transfer flow rates (volume)
S100
11...220 m
3
/h / 1660...33210 bbl/day
S150
25...500 m
3
/h / 3774...75478 bbl/day
S250
60...1200 m
3
/h / 9057...181147 bbl/day
Assumes operating density 1000 kg/m
3
/ 62.4 lb/ft
3
Ambient temperature
Ambient temperatureAmbient temperature
Ambient temperature
Compact version with Aluminium
converter
-40...+60°C / -40+140°F
Extended temperature range: 65°C / 149°F for some I/O options. For more
information contact manufacturer.
Compact version with Stainless Steel
converter
-40...+55°C / -40+130°F
Remote versions -40...+65°C / -40+149°F
Process temperature
Process temperatureProcess temperature
Process temperature
Flanged connection -45+130°C / -49+266°F
Hygienic connection (S100 only)
Nominal pressure at 20
Nominal pressure at 20Nominal pressure at 20
Nominal pressure at 20°C / 68
C / 68C / 68
C / 68°F
FF
F
Measuring tube (Duplex UNS S31803)
Measuring tube (Duplex UNS S31803) Measuring tube (Duplex UNS S31803)
Measuring tube (Duplex UNS S31803)
PED 97/23/EC -1150 barg / -14.52175 psig
FM -1140 barg / -14.52030 psig
CRN / ASME B31.3 -1100 barg / -14.51450 psig
Measuring tube (Super Duplex UNS S32760)
Measuring tube (Super Duplex UNS S32760) Measuring tube (Super Duplex UNS S32760)
Measuring tube (Super Duplex UNS S32760)
PED 97/23/EC -1180 barg / -14.52610 psig
FM -1140 barg / -14.52030 psig
CRN / ASME B31.3 (pending) -1130 barg / -14.51885 psig
Outer cylinder
Outer cylinderOuter cylinder
Outer cylinder
Non PED / CRN approved Typical burst pressure > 100 barg / 1450 psig
PED approved secondary containment -1...40 barg / -14.5...580 psig
-1...150 barg / -14.5...2175 psig (Duplex option)
Fluid properties
Fluid propertiesFluid properties
Fluid properties
Permissible physical condition Liquids, gases, slurries
Permissible gas content (volume) Contact manufacturer for information.
MA_OPTIMASS_2400_en_140515_4003533101_R01.book Page 32 Thursday, July 31, 2014 5:08 PM