Manual

TECHNICAL DATA 6
33
OPTIMASS 2400
www.krohne.com07/2014 - 4003533101- MA OPTIMASS 2400 R01 en
Permissible solid content (volume) Contact manufacturer for information.
Protection category (acc. to EN 60529) IP 67, NEMA 4X
Installation conditions
Inlet runs None required
Outlet runs None required
Materials
Measuring tube Stainless Steel UNS S31803 (1.4462)
Optional UNS S32760 (1.4501)
Spigot Stainless Steel UNS J92205 (1.4470)
Optional UNS J93404 (1.4469)
Flanges Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified
Optional Stainless Steel UNS S31803 (1.4462) (NACE approved)
Optional UNS S32760 (1.4501) (NACE approved)
Outer cylinder Stainless Steel AISI 304 / 304L (1.4301 / 1.4307) dual certified
Optional Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified
Optional Stainless Steel UNS S31803 (1.4462) 1
Heating jacket version
Heating jacket versionHeating jacket version
Heating jacket version
Heating jacket Stainless Steel 316L (1.4404)
Note: the outer cylinder is in contact with the heating medium
Remote versions
Remote versionsRemote versions
Remote versions
Junction box Die cast Aluminium (polyurethane coating)
Process connections
Flange
FlangeFlange
Flange
DIN DN100300 / PN16160
ASME 4...12" / ASME 1501500
JIS 100A / 10...20K
Hygienic
HygienicHygienic
Hygienic
Tri-clover 4"
Tri-clamp DIN 32676 DN100
Tri-clamp ISO 2852 4"
DIN 11864-2 Form A DN100
Male thread DIN 11851 DN100
Male thread SMS 4"
Male thread IDF / ISS 4"
Male thread RJT 4"
Electrical connections
Electrical connections For full details, including: power supply, power consumption etc., see
technical data for the relevant converter.
I/O For full details of I/O options, including data streams and protocols, see
technical data for the relevant converter.
MA_OPTIMASS_2400_en_140515_4003533101_R01.book Page 33 Thursday, July 31, 2014 5:08 PM