Manual
6 TECHNICAL DATA
38
OPTIMASS 2400
www.krohne.com 07/2014 - 4003533101- MA OPTIMASS 2400 R01 en
6.6 Guidelines for maximum operating pressure
Notes:
• Ensure that the meter is used within its operating limits
• All hygienic process connections have a maximum operating rating of 10 barg
at 130°C / 145 psig at 266°F
Linear de-rating of PED certified secondary containment
Pressure / temperature de-rating, all meter sizes in metric (flanged connections as
Pressure / temperature de-rating, all meter sizes in metric (flanged connections as Pressure / temperature de-rating, all meter sizes in metric (flanged connections as
Pressure / temperature de-rating, all meter sizes in metric (flanged connections as
per EN 1092-1:2007)
per EN 1092-1:2007)per EN 1092-1:2007)
per EN 1092-1:2007)
X temperature [°C]
Y pressure [barg]
1 Measuring tube (UNS S32760) PED certification
2 Measuring tube (UNS S31803) PED certification
3 Measuring tube (UNS S31803 / S32760) FM certification
4 Measuring tube (UNS S31803) CRN certification
Outer cylinder material -45°C20°C 130°C
304 / L or 316 / L 40 barg 40 barg 32 barg
UNS S31803 150 barg 150 barg 100 barg
MA_OPTIMASS_2400_en_140515_4003533101_R01.book Page 38 Thursday, July 31, 2014 5:08 PM