Owner's manual
TECHNICAL DATA 8
109
OPTISONIC 6300
www.krohne.com07/2009 - 4000263902 - HB OPTISONIC 6300 R03 en
Media properties
Media propertiesMedia properties
Media properties
Physical condition Liquids
Viscosity < 100 cSt (general guideline)
For detailed information please contact your local representative.
Permissible gas content (volume) ≤ 2%
Permissible solid content
(volume)
≤ 5%
Recommended flow velocity 0.5...20 m/s
Other conditions
Other conditionsOther conditions
Other conditions
Protection category acc. to
IEC 529 / EN 60529
W (Wall) version signal converter:
IP 65 (acc. to NEMA 4/4x)
F (Field) version signal converter:
IP 66/67 (acc. to NEMA 4x/6)
All sensors:
IP 67 (acc. to NEMA 6)
Vibration resistance IEC 68-2-64
Shock resistance IEC 60068-2-27
Installation condititions
Measurement configuration Single path, single pipe or dual path / dual pipe
Inlet run ≥ 10 DN straight length
Outlet run ≥ 5 DN straight length
Dimensions and weights See chapter "Dimensions and weights"
Materials
Sensor Standard
StandardStandard
Standard
Anodised aluminum
Option stainless steel / eXtended Temperature (small / medium
Option stainless steel / eXtended Temperature (small / medium Option stainless steel / eXtended Temperature (small / medium
Option stainless steel / eXtended Temperature (small / medium
version)
version)version)
version)
Rail construction: 1.4404 (AISI 316L)
Cable connection:1.4404, PSU with FKM O-ring
Converter Standard
StandardStandard
Standard
F version: die-cast aluminum, polyurethane coated
W version: polyamide-polycarbonate
Option
OptionOption
Option
F version: stainless steel 316 L (1.4408)
Electrical connections
Voltage Standard: 100…230 VAC (-15% / +10%), 50/60 Hz
Option: 24 VAC/DC (AC: -15% / +10%; DC: -25% / +30%)
Power consumption AC: 22 VA
DC: 12 W
Signal cable double shielded, 2 internal triax, available lengths:
5 m / 15 ft (standard), maximum length 30 m / 90 ft
Cable entries Standard: M20 x 1.5
Option: ½" NPT, PF ½
.book Page 109 Tuesday, August 18, 2009 4:51 PM