Instruction Manual

vessel wall (with solids). To adapt the sensor to these dierent
conditions, you should rst select in this menu item "Liquid" or
"Solid".
Medium
Liquid
With solids, you can also choose between "Powder/Dust",
"Granular/Pellets" or "Ballast/Pebbels".
Through this additional selection, the sensor is adapted
perfectly to the product and measurement reliability, partic-
ularly in products with bad reective properties, is considerably
increased.
Enter the requested parameter via the appropriate keys, save
your settings and jump to the next menu item with the [–>] key.
Apart from the medium also the vessel form can inuence the
measurement. To adapt the sensor to these conditions, this
menu item oers (depending on either liquid or solid is
detected) dierent options. For Liquid these are Storage tank,
Stilling tube, Open vessel or Stirred vessel, for Solid Silo or
Bunker.
Vessel shape
Storage tank
Enter the requested parameter via the appropriate keys, save
your settings and jump to the next menu item with the [–>] key.
To suppress uctuation in the measured value display, e.g.
caused by a turbulent product surface, an integration time can
be set. This time can be between 0 and 999 seconds. Please
note that the reaction time of the entire measurement will be
longer and the sensor will react to quick changes of the
measured value with a corresponding delay. In general, a time
of a few seconds is sucient to smooth the measured value
display.
Damping
0 s
Vessel shape
Damping
OPTISOUND 3010 C - 4 20 mA/HART 29
Setup with the indicating/adjustment module
30503-EN-050914