Instruction Manual

Process conditions
Vessel pressure -20 200 kPa (-0.2 2.0 bar/-2.9 29 psi)
Process temperature (transducer tem-
perature)
-40 +80°C (-40 +176°F)
Vibration resistance mechanical vibrations with 4 g and 5 100 Hz
4)
Electromechanical data
Cable entry
- Single chamber housing
l 1x cable entry M20x1.5 (cable-ø 5 9 mm),
1x blind stopper M20x1.5
or:
l 1x closing cap ½ NPT, 1x blind stopper
½ NPT
- Double chamber housing
l 1x cable entry M20x1.5 (cable-ø 5 9 mm),
1x blind stopper M20x1.5
or:
l 1x closing cap ½ NPT, 1x blind stopper
½ NPT
Spring-loaded terminals for wire cross sections up to 2.5 mm²
Indicating and adjustment module
Power supply and data transmission through sensor via gold-plated sliding contacts
(I²C bus)
Indication LC display in full dot matrix
Adjustment elements 4 keys
Protection
- unassembled IP 20
- mounted into the sensor without
cover
IP 40
Materials
- Housing ABS
- Inspection window Polyester foil
Supply voltage
Supply voltage
- non-Ex instrument 14 36 VDC
- EEx ia instrument 14 30 VDC
4)
Tested acc. to the regulations of German Lloyd, GL directive 2
40 OPTISOUND 3010 C - 4 20 mA/HART
Supplement
30503-EN-050914