Owner's manual

Surface quality
- Standard R
a
approx. 3 µm (approx. 1.18
-4
in)
- Hygienic version 3A (OPTISWITCH
5150 C)
R
a
<0.8 µm (<3.15
-5
in)
Process ttings
- Thread G¾ A, ¾ NPT, G1 A, 1 NPT
- Flanges DIN from DN 25, ANSI from 1"
- hygienic ttings Bolting DN 40 PN 40, Tri-Clamp 1", Tri-Clamp
1½" PN 10, conus DN 25 PN 40, Tuchenhagen
Varivent DN 50 PN 10
High voltage test (enamel) max. 5 KV
Gas-tight leadthrough (optional)
- leakage rate <10
-6
mbar l/s
- pressure resistance PN 64
- hygienic ttings Bolting DN 40 PN 40, Tri-Clamp 1", Tri-Clamp
1½" PN 10, conus DN 25 PN 40, Tuchenhagen
Varivent DN 50 PN 10
Output variable
Output relay output (DPDT), 2 oating spdts
Turn-on voltage
- min. 10 mV
- max. 253 VAC, 253 VDC
Switching current
- min. 10 µA
- max. 3 AAC, 1 ADC
Breaking capacity
- min. 50 m
W
- max.
750 VA AC, 54 WDC
If inductive loads or stronger currents are
switched through, the gold plating on the relay
contact surface will be permanently damaged.
The contact is then no longer suitable for
switching low-level signal circuits.
Contact material (relay contacts) AgNiorAgSnO and Au plated
OPTISWITCH 5100 C, 5150 C - with relay output 25
Supplement
30426-EN-060831