Manual

1 Unscrew the housing cover
2 Loosen compression nut of the cable entry
3 Remove approx. 10 cm (4 in) of the cable mantle, strip
approx. 1 cm (0.4 in) insulation from the ends of the
individual wires
4 Insert the cable into the sensor through the cable entry
5 Open the terminals with a screwdriver
6 Insert the wire ends into the open terminals according to
the wiring plan
7 Tighten the terminals with a screwdriver
8 Check the hold of the wires in the terminals by lightly
pulling on them
9 Tighten the compression nut of the cable entry, the seal
ring must completely encircle the cable
10 Screw the housing cover back on
The electrical connection is hence nished.
5.3 Wiring plan, single chamber housing
The following illustrations apply to the non-Ex as well as to the
EEx d version.
1
4
44
2 3
Fig. 10: Material versions, single chamber housing
1 Plastic (not with EExd)
2 Aluminium
3 Stainless steel (not with EExd)
4 Filter element for pressure compensation (not with EExd)
Housing overview
OPTISWITCH 5200 C, 5250 C - with contactless electronic switch 17
Connecting to voltage supply
30433-EN-060831