Manual

OPTISWITCH 5200 C, 5250 C of 316L/
Hastelloy C4 (2.4610)
-50 +150 °C (-58 +302 °F)
Process temperature (thread or ange
temperature) with temperature adapter
(option)
- OPTISWITCH 5200 C, 5250 C of
316L/Hastelloy C4
-50 +250 °C (-58 +482 °F)
- OPTISWITCH 5200 C, 5250 C with
ECTFE coating
-50 +150 °C (-58 +302 °F)
- OPTISWITCH 5200 C, 5250 C with
PFA coating
-50 +150 °C (-58 +302 °F)
1
2
3
-50˚C
(-58˚F)
50˚C
(122˚F)
40˚C
(104˚F)
-40˚C
(-40˚F)
70˚C
(158˚F)
0˚C
(32˚F)
100˚C
(212˚F)
150˚C
(302˚F)
200˚C
(392˚F)
250˚C
(482˚F)
Fig. 14: Ambient temperature - Product temperature
1 Product temperature
2 Ambient temperature
3 Temperature range with temperature adapter
Viscosity - dynamic 0.1 10,000 mPas(requirement: with density
1)
Density 0.7 2.5 g/cm³ (0.025 0.09 lbs/in³);
0.5 2.5 g/cm³ (0.018 0.09 lbs/in³) by
switching over
Supplement
28 OPTISWITCH 5200 C, 5250 C - with contactless electronic switch
30433-EN-060831