User guide

5 OPERATION
46
OPTISYS SLM 2100
www.krohne.com 03/2014 - 4002737302 - MA OPTISYS SLM 2100 R02 en
B3, logbooks
B4, information
5.6.3 Menu C, setup
C1, measuring
Level Designation / function Settings / descriptions
This menu groups several functions which allow to display the corresponding actual reading.
B3.1
B3.1B3.1
B3.1 status log Log for information, errors and warnings.
Level Designation / function Settings / descriptions
This menu groups several other menus which contain device specific information.
B4.1
B4.1B4.1
B4.1 Device serial no. This menu shows the serial number of the device
B4.2
B4.2B4.2
B4.2 Mainboard This menu gives information about the main board.
1st line: ID No. of the circuit board
2nd line: software version
3rd line: production date
B4.3
B4.3B4.3
B4.3 Sensor electronic This menu gives information about the sensor electronic.
1st line: ID No. of the sensor
2nd line: software version
3rd line: production date
Level Designation / function Settings / descriptions
This menu groups several other menus in which the measuring functions can be set.
C1.1 Measuring function This menu shows the different measurement functions: "Level", "Profile",
"Zone Tracking" and "Manual operation".
C1.2 Measuring mode This menu shows the different measurement mode of the level
measurement and can be switched from "Depth" to "Height".
C1.3 Definition fluff This menu shows the concentration of the fluff and can be set.
C1.4 Def. sludge blanket This menu shows the concentration of the sludge blanket and can be set.
C1.5 Hysteresis This function allows to set the hysteresis value of the zone tracking mode
(This menu is displayed only if zone tracking is selected in C3.1.1); Range:
05g/l
C1.6 Tracking time Definition time period the sensor is remaining in parking position, when
elapsed the sludge level will be tracked again (This menu is displayed only if
zone tracking is selected in C3.1.1); Range: 20999 s
C1.7 Tracking position Definition of the relative parking position of the sensor above the sludge
level (This menu is displayed only if zone tracking is selected in C3.1.1);
Range: 0.05-0.3 m
C1.8 Start signal This menu shows the start signal for the measurement and can be selected
between "Timer" (via build in timer) or "Trigger input" (via external switch on
control input 1 and/or 2).
C1.9 Timer interval This menu shows the timer interval for starting the measurement and can
be set in minutes. (This menu is displayed only if "Timer" is selected in C1.6.)
C1.10 Units This menu groups several functions to define the units of the measuring
results. These units are used for all values of the related unit group on the
display (measuring screen and parameters).
C1.10.1 Height / Depth This function allows to define the unit for level measurement. Options: m,
feet, inch, cm
C1.10.2 Temperature This function allows to define the temperature unit. Options: °C, °F, K
C1.10.3 Concentration This function allows to define the concentration unit. Options: g/l, mg/l