C4, extended setup
Level Designation / function Settings / descriptions
This submenu allows to set the initial parameters for commissioning of the meter.
C4.1 Maximum depth Definition of the maximum depth.
C4.2 Start position Definition of the start position.
C4.3 Blind zone Definition of the blind zone.
C4.4 Rake height Definition of the rake height.
C4.5 Cleaning Settings of the corresponding relay.
C4.5.1 Activation This function allows to activate cleaning:
Options:
• off
• timer interval
• counter interval
C4.5.2 Counter interval This menu defines the number of measurement cycles between cleaning
(This menu is displayed only if counter interval is selected in C4.5.1).
C4.5.3 Timer interval This menu defines the time of the cleaning intervals (This menu is displayed
only if timer interval is selected in C4.5.1);
Range: 10…999 min
C4.5.4 Pump lead time Definition of pump lead time. (This menu is displayed only if cleaning is
activated in C4.5);
Range: 0…120 s
C4.5.5 Cleaning cycle In this menu a the number of cleaning cycles can be set;
Range: 0…99
C4.5.6 External pump This menu defines if the external pump is controlled by the relays K3
(Choose "yes" or "no").