Owner's manual

TECHNICAL DATA 7
53
OPTITEMP TRA/TCA
www.krohne.com08/2010 - 4000630501 - MA OPTITEMP TRA/TCA R01 en
7.5 Process connections
Insertion-type thermometer with thermowell
Insertion-type thermometer without thermowell
Threaded thermometer with and without neck tube
Flange thermometer with neck tube
Type of process connection Materials Ø of thermowell
[mm] ["]
Compression fitting 1.4571 9 / 11 / 12 0.35 / 0.43 / 0.47
Type of process connection Material Ø of immersion tube
[mm] ["]
Compression fitting 1.4571 6 0.24
Type of process connection Materials Ø of thermowell
[mm] ["]
G½" 1.4571 9 / 11 / 12 0.35 / 0.43 / 0.47
G¾" 11 / 12 0.43 / 0.47
G1" 11 / 12 0.43 / 0.47
½"NPT 9 / 11 / 12 0.35 / 0.43 / 0.47
¾"NPT 11 / 12 0.43 / 0.47
INFORMATION!
The manufacturer offers the flange thermometer with process connections as per DIN EN 1092-
1 or ASME/ANSI 16.5. For DIN flanges the sealing surface complies with Form B1 and with ASME
flanges, type "RF".
Type of process connection Material Ø of thermowell
[mm] ["]
DN25 / PN40 1.4571 9 / 11 / 12 0.35 / 0.43 / 0.47
DN50 / PN40 11 / 12 0.43 / 0.47
1" / 150 lb 9 / 11 / 12 0.35 / 0.43 / 0.47
1½" / 150 lb 11 / 12 0.43 / 0.47
1" / 300 lb 11 / 12 0.43 / 0.47
1½" / 300 lb 11 / 12 0.43 / 0.47
.book Page 53 Tuesday, August 17, 2010 12:18 PM