Instruction Manual

7 TECHNICAL DATA
56
OPTITEMP TRA/TCA PLUS
www.krohne.com 01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01
Flange thermometer according to DIN 43772
Flange thermometer according to DIN 43772Flange thermometer according to DIN 43772
Flange thermometer according to DIN 43772
Figure 7-8: Flange thermometer according to DIN 43772
1 TRA/TCA-TF31 (conical thermowell, one-piece, bar stock)
2 TRA/TCA-TF33 (straight thermowell, multipart, welded)
TRA/TCA-TF31
Neck tube length
"a"
Insertion length
"b"
Cone length "d" Thermowell
length "c"
Measuring insert
length
[mm] ["] [mm] ["] [mm] ["] [mm] ["] [mm] ["]
165 6.5 130 5.1 65 2.6 200 7.9 375 14.8
190 5 125 4.9 260 10.2 435 17.1
TRA/TCA-TF33
Neck tube length "a" Insertion length "b" Thermowell length "c" Measuring insert
length
[mm] ["] [mm] ["] [mm] ["] [mm] ["]
165 6.5 110 4.3 200 7.9 322 12.7
170 6.7 260 10.2 382 15.0
260 10.2 350 13.8 472 18.6
410 16.1 500 19.7 622 24.5
INFORMATION!
Tolerances of all thermowell and insertion lengths:
±
1 mm / 0.04"
Tolerances of all measuring insert lengths: +2 mm, -0 mm / +0.08", -0"
.backup.book Page 56 Tuesday, January 10, 2012 11:57 AM