Instruction Manual

7 TECHNICAL DATA
60
OPTITEMP TRA/TCA PLUS
www.krohne.com 01/2012 - 4000630301 - MA OPTITEMP TRA/TCA Plus R01
7.3.4 Thermowells: Diameter, wall thickness, tips
Figure 7-11: Thermowell designs
1 Straight thermowell, multipart, welded
2 Straight thermowell, one-piece, bar stock
3 Conical-straight thermowell, one-piece, bar stock
4 Conical thermowell, one-piece, bar stock
5 Reduced thermowell, one-piece, bar stock
Type Design Øa Øb (Hole) Øc
[mm] ["] [mm] ["] ["] ["]
TRA/TCA-T30 3 24 h7 0.94 7 0.28 12.5 0.49
TRA/TCA-TF31
TRA/TCA-TS32,
TRA/TCA-TF33,
TRA/TCA-TS35
1 9x1 0.37 x 0.04 7 0.28 - -
10 x 1 0.41 x 0.04 8 0.31
11 x 2 0.45 x 0.08 7 0.28
12 x 2 0.49 x 0.08 8 0.31
12 x 2.5 0.49 x 0.10 7 0.28
TRA/TCA-TS36 2 17 0.67 7 0.28
TRA/TCA-TS37 2 17 0.67 7 0.28
TRA/TCA-TS52 2 16 0.63 6.5 0.26
TRA/TCA-TS53 4 16 0.63 6.5 0.26 13 0.51
22 0.87 6.5 0.26 16 0.63
TRA/TCA-TS54 5 16 0.63 6.5 0.26 13 0.51
22 0.87 6.5 0.26 13 0.51
TRA/TCA-TF55 2 19 0.75 6.5 0.26 - -
TRA/TCA-TF56 4 22 0.87 6.5 0.26 16 0.63
25 0.98 6.5 0.26 19 0.75
.backup.book Page 60 Tuesday, January 10, 2012 11:57 AM