Owner manual

2 INSTALLATION
14
OPTIWAVE 5200 C/F
www.krohne.com 04/2013 - 4001905802 - AD ATEX OPTIWAVE 5200 R02 en
Compact version
Equipment category 2 G or EPL Gb: Ex ia and Ex d ia devices
Equipment category 3 G or EPL Gc: Ex ic devices
Temperature
class
Maximum ambient temperature Max. flange
temperature
PP Wave Horn PTFE Wave Horn
Wave-Stick
Metallic Horn
(standard
temperature)
Wave-Guide
Metallic Horn
(high-
temperature)
[°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F]
T6 +46 +115 +46 +115 +46 +115 +46 +115 +45 +113
+41 +106 +42 +108 +41 +106 +44 +111 +55 +131
+38 +100 +40 +104 +39 +102 +43 +109 +60 +140
T5 +53 +127 +55 +131 +54 +129 +58 +136 +75 +167
+40 +104 +44 +111 +43 +109 +54 +129 +100 +212
T4 +77 +171 +77 +171 +77 +171 +79 +174 +85 +185
+69 +156 +71 +160 +70 +158 +76 +169 +110 +230
- - +57 +135 +54 +129 +71 +160 +135 1 +275 1
T3 - - +50 +122 +48 +118 +68 +154 +150 1 +302 1
- - - - - - +64 +147 +180 1 +356 1
- - - - - - +61 +142 +200 1 +392 1
T2 - - - - - - +53 +127 +250 1 +482 1
1 Make sure that gasket temperature is in the specified limits. For more data, refer to the handbook.
Temperature
class
Minimum ambient temperature Min. flange
temperature
PP Wave Horn
Wave-Stick
PTFE Wave Horn Metallic Horn
(standard
temperature)
Wave-Guide
Metallic Horn
(high-
temperature)
[°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F]
T6...T2 -40 -40 -40 -40 -40 -40 -40 -40 -40 1 -40 1
- - -36 -32 -35 -31 -37 -34 -50 1 -58 1
- - - - - - -37 -34 -60 1 -76
1 Make sure that gasket temperature is in the specified limits. For more data, refer to the handbook.