Owner manual

2 INSTALLATION
16
OPTIWAVE 5200 C/F
www.krohne.com 04/2013 - 4001905802 - AD ATEX OPTIWAVE 5200 R02 en
Remote (Field) version (antenna housing only)
Equipment category 2 G or EPL Gb: Ex ia and Ex d ia devices
Equipment category 3 G or EPL Gc: Ex ic devices
Temperature
class
Maximum ambient temperature Max. flange
temperature
PP Wave Horn PTFE Wave Horn
Wave-Stick
Metallic Horn
(standard
temperature)
Wave Guide
Metallic Horn
(high-
temperature)
[°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F]
T6 +46 +115 +46 +115 +46 +115 +46 +115 +45 +113
+41 +106 +41 +106 +41 +106 +44 +111 +55 +131
+39 +102 +39 +102 +39 +102 +43 +109 +60 +140
T5 +54 +129 +54 +129 +54 +129 +59 +138 +75 +167
+43 +109 +43 +109 +41 +106 +55 +131 +100 +212
T4 +77 +171 +77 +171 +77 +171 +79 174 +85 +185
+70 +158 +71 +160 +70 +158 +77 +171 +110 +230
- - +55 +131 +53 +127 +72 +162 +135 1 +275 1
T3 - - +48 +118 +45 +113 +66 +151 +150 1 +302 1
- - - - - - +63 +145 +180 1 +356 1
- - - - - - +57 +135 +200 1 +392 1
T2 - - - - - - +53 +127 +250 1 +482 1
1 Make sure that gasket temperature is in the specified limits. For more data, refer to the handbook.
Temperature
class
Minimum ambient temperature Min. flange
temperature
PP Wave Horn
Wave-Stick
PTFE Wave Horn Metallic Horn
(standard
temperature)
Wave Guide
Metallic Horn
(high-
temperature)
[°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F] [°C] [°F]
T6...T2 -40 -40 -40 -40 -40 -40 -40 -40 -40 1 -40 1
- - -36 -33 -35 -31 -39 -38 -50 1 -58 1
- - - - - - -37 -34 -60 1 -76 1
1 Make sure that gasket temperature is in the specified limits. For more data, refer to the handbook.
INFORMATION!
Remote converter
Remote converterRemote converter
Remote converter
The maximum ambient temperature, T
a
, permitted depends on the temperature class:
T
a
= +60
°
C for class T6
T
a
= +70
°
C for class T5
T
a
= +80
°
C for class T4