Manual

TECHNICAL DATA 8
101
OPTIWAVE 5200 C/F
www.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en
8.2 Technical data
INFORMATION!
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Measuring principle 2-wire loop-powered level transmitter; X-band (10 GHz) FMCW radar
Application range Level measurement of liquids, pastes and slurries
Primary measured value Distance and reflection
Secondary measured value Level, volume, mass and flow rate
Design
Construction The measurement system consists of a measuring sensor (antenna) and a signal
converter
Options Integrated LCD display (-20..+60°C/ -4+140°F); if the ambient temperature is not
in these limits, the display switches off automatically
High-temperature (HT) extension (if the process connection temperature is more
than +150°C / +302°F - Metallic Horn antenna only)
Straight antenna extensions
Max. extension length, PTFE Wave Horn antenna: 300 mm / 11.8¨;
Max. extension length, Metallic Horn antenna: 1000 mm / 39.4¨
"S" antenna extension
- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options
"L" (right angle) antenna extension
- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options
Antenna purging system
- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options
Heating / cooling system (with or without the antenna purging system)
- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options
Signal cable for remote housing version (refer to cable properties in "Electrical
connection: Remote device version")
Weather protection - for the compact version or the antenna housing (remote
version). It cannot be ordered after delivery of the device.
Max. measuring range PTFE and PP Wave Horn antennas:
PTFE and PP Wave Horn antennas:PTFE and PP Wave Horn antennas:
PTFE and PP Wave Horn antennas:
20 m / 65.6 ft
DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):
DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):
DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):
10 m / 32.8 ft
DN150 / DN200 Metallic Horn antennas:
DN150 / DN200 Metallic Horn antennas:DN150 / DN200 Metallic Horn antennas:
DN150 / DN200 Metallic Horn antennas:
30 m / 98.4 ft
Wave Guide antenna:
Wave Guide antenna:Wave Guide antenna:
Wave Guide antenna:
6m/ 19.7ft
Also depends on the dielectric constant of the product and the installation type.
Refer also to "Antenna selection".
Min. tank height 1m/ 3.3ft
Top dead zone Minimum value: Antenna length + antennna extension length + 100 mm / 3.9¨