Manual

DESCRIPTION OF HART INTERFACE 9
133
OPTIWAVE 5200 C/F
www.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en
View Menu
Access rights
Access level
Rd
Method Login
Method Entry Code
HART Variables
1 Poll addr / 2 Tag / 3 Hardware rev
Rd
/ 4 Software rev
Rd
/ 5Descriptor/ 6Date/ 7Message/
8 Manufacturer
Rd
/ 9 Model
Rd
/ Dev id
Rd
/ Universal id
Rd
/ Fld dev rev
Rd
/ Num req preams
Rd
/
Num resp preams
Rd
/ Write protect
Rd
/ Production number
Rd
/ Final asmbly num
Rd
/ PV is / SV is / TV is /
QV is
1 Current Output Calibration is available only if the service password is used
Measurements
Measurements Level Value / Distance Value / Volume Value / Ullage Value / Reflection Value
Output Level value / Loop curent / % Range
Yt diagram
Diag / Service
Standard Status Device status PV Analog Channel Saturated / Configuration
changed
Device-specific status Device failures Sensor Microwave error / Current Output Drift /
Sensor ROM error / Sensor RAM error /
Sensor EEPROM error / Converter ROM error /
Converter RAM error / Converter EEPROM error
Sensor No Signal / Sensor Not Compatible /
Temperature Out of Range /
Internal Communication Error /
Sensor Voltage Error / Converter Voltage Error
Peak Lost Error / Overfill Error
Device Warning
(Maintenance
Required)
Empty Spectrum Invalid / Signal Weak / Signal
Strong / Bad Measurement Quality /
Temperature Below -35°C/
Temperature Above +75°C
Device Warning (Out of
Specification)
Overfill Warning / Peak Lost Warning /
Temperature Out of Range Warning
Info First Start / Spectrum Quality Bad /
Peak Lost in Tank Bottom /
Temperature out of range for HMI
Toolbar
Status Bar
Update