Manual
ELECTRICAL CONNECTIONS 4
49
OPTIWAVE 5200 C/F
www.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en
Equipment needed
Figure 4-8: Equipment needed to prepare the signal cable
1 Remote coverter
2 Antenna housing
3 Signal cable (supplied on request for non-Ex devices) - for more data, refer to
How to prepare a signal cable supplied
by the customer
on page 47
4 Small slotted-tip screwdriver (not supplied)
Connections between the remote converter and the antenna housing
Figure 4-9: Connections between the remote converter and the antenna housing
1 Remote coverter
2 Antenna housing
3 Power supply: voltage in -
4 Power supply: voltage in +
5 Signal cable B
6 Signal cable A
7 Shielding wire (attached to Faston connectors in the housings of the remote converter and the antenna housing)