Manual

6 OPERATION
68
OPTIWAVE 5200 C/F
www.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en
6.3.5 Function description
1.0.0 Information (Info.) menu
Menu
No.
Function Function description Selection list Default
1.1.0 IDENT.
1.1.1 SERIAL NUM. The device serial number. Read only.
1.1.2 CONV.FIRM.VER The converter firmware version. Read only.
1.1.3 SEN.FIRM.VER The sensor firmware version. Read only.
1.1.4 HMI.FIRM.VER The HMI (device display screen) firmware
version.
Read only.
1.2.0 OUTPUT I
1.2.1 SUMMARY I This shows the settings at this time for the
output function (OUTPUT FUNC.), output
range (RANGE I), 4 mA setting (SCALE 4mA),
20 mA setting (SCALE 20mA), and error delay
(ERROR DELAY).
Read only.
1.3.0 HISTORY
1.3.1 ERROR RECORD A log of device errors. Push [>
>>
>] to read the
errors. Push [
] or [
] to scroll up or down
the list. Each error is identified by a code.
Push [>
>>
>] again to show the number of
incidents and the time since the last incident
in days, hours, minutes and seconds. For
more data about errors, refer to
Status and
error messages
on page 84.
Read only.