Supplementary Installation and Operating Instructions UFC 030 HART
HC275, FC375, AMS, PDM
Attachment B
Configure
Compare
Clear Offline
-----------------------------------
Status/Conditions
Process Variables
Scan Device
-----------------------------------
Calibration Management
Diagnostics and Test
Calibrate
Reset
Paramter Protection
-----------------------------------
Rename
Unassign
Assign / Replace
-----------------------------------
Audit Trail
Record Manual Event
Drawings / Notes ...
Help ...
Designations:
Opt
Optional, dependent on device
implementation / configuration
Rd
Read-only
Loc
Local AMS, affects only AMS views
UFC 030 HART Menu Tree AMS
Basic Setup
Sensor
•Zero Value
• Flow Direction
Process Input
•Flow Units
• Full Scale
•Master TC
•L.F. Cutoff
• Cutoff on
Opt
• Cutoff off
Opt
Correction
• Converter Function
Current / Pulse Output
• Function I
•Range I
• Function P
Opt
•Output
Opt
Display
• Function Totalizer
• Display Totalizer
Sensor
Meter
• Meter Size Table
Opt
•Meter Size Units
Opt
•Meter Size
•GK Value
Volume Flow Limits
• Upper Sensor Limit
Rd
• Minimum Span
Rd
Heat Flow Limits
Opt
• Upper Sensor Limit
Rd
• Minimum Span
Rd
•Zero Value
•Flow Direction
Sensor
Opt
• Dead Time
•Trigger Select
•Trigger Level 1
• Trigger Margin
• Sensor Frequency
Correction
Version
• Converter Function
•Temperature Units
Opt
• Input 1 4mA
Opt
• Input 1 20mA
Opt
• Pressure Units
Opt
• Input 2 4mA
Opt
• Input 2 20mA
Opt
•K0
Opt
•K1
Opt
•K2
Opt
• Density 15
Opt
• Heat Flow Units
Opt
• Full Scale
Opt
Analog Input Calibration
Opt
• Input 1 0mA
• Input 1 20mA
• Input 2 0mA
• Input 2 20mA
Process Input
•Flow Units
• Full Scale
•Master TC
L.F. Cutoff
•L.F. Cutoff
• Cutoff on
Opt
• Cutoff off
Opt
• VOS Min/Max Units
•Min VOS
•Max VOS
Current Output
Current Output
• Function I
•Direction I
•Range I
•I 0%
• I 100%
•Limit
•Calibration 4mA
Opt
• Calibration 20mA
Opt
Pulse Output
• Function P
Opt
•Direction P
Opt
•Digital Output
Opt
•Trip. Point 1
Opt
•Trip. Point 2
Opt
• Time Constant
Opt
•Output
Opt
•PulserateUnits
Opt
•Pulserate
Opt
• Units Pulse/Unit
Opt
• Pulse/Unit
Opt
•Pulsewidth
Opt
Display
•Display Flow
• Function Totalizer
•Display Totalizer
• Volume Units
Opt
•Energy Units
Opt
• VOS Units
•Analog Input
Opt
•Signal Gain
Local Display
•Language
• Cyclic Display
• Error Messages
•Date
•Text Volume
•Text Time
•Unit Volume
•Unit Time
Display Formats
•Format Flow
Loc
•Format Heat Flow
Opt, Loc
•Format Volume
Loc
• Format Energy
Opt, Loc
3
2
KROHNE UFC 030 HA 45e70201 (1/3)