User guide

4 OPERATION
20
UFC 400
www.krohne.com 05/2013 - 4002813701 - AD FF UFC 400 R01 en
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
11
1111
11
FD_EXTENDED_MAP_
11
R/W Field Diagnostics of "Process : Signal Unreliable" Uninitialized
Setting:
(28) Time of Flight / (29) Path 3 unreliable / (30) Path 2
unreliable / (31) Path 1 unreliable
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
12
1212
12
FD_EXTENDED_MAP_
12
R/W Field Diagnostics of "Process : Signal Lost" Uninitialized
Setting:
(29) Signal lost path 3 / (30) Signal lost path 2 / (31) Signal lost
path 1
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
13
1313
13
FD_EXTENDED_MAP_
13
R/W Field Diagnostics of "Process : Empty Pipe" Uninitialized
Setting:
(31) Empty Pipe
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
14
1414
14
FD_EXTENDED_MAP_
14
R/W Field Diagnostics of "Electronics : IO Connection" Uninitialized
Setting:
(28) IO B Connect. Control Input / (29) IO B Connect. Current
In-/Output / (30) IO A Connect. Control Input / (31) IO A
Connect. Current In-/Output
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
15
1515
15
FD_EXTENDED_MAP_
15
R/W Field Diagnostics of "Process : Current input" Uninitialized
Setting:
(30) IO B Error Current / (31) IO A Error Current
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
16
1616
16
FD_EXTENDED_MAP_
16
R Field Diagnostics of "M Process" Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
17
1717
17
FD_EXTENDED_MAP_
17
R/W Field Diagnostics of "M Configuration" Uninitialized
Setting:
(30) Backup 2 Data Faulty / (31) Backup 1 Data Faulty
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
18
1818
18
FD_EXTENDED_MAP_
18
R/W Field Diagnostics of "M Electronics" Uninitialized
Setting:
(29) Backplane Difference / (30) Factory Data Faulty / (31)
Backplane Data Faulty
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
19
1919
19
FD_EXTENDED_MAP_
19
R Field Diagnostics of "M Sensor" Uninitialized
Setting:
(00) Reserved
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
20
2020
20
FD_EXTENDED_MAP_
20
R/W Field Diagnostics of "S Process" Uninitialized
Setting:
(31) Velocity Out of Range
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
21
2121
21
FD_EXTENDED_MAP_
21
R/W Field Diagnostics of "S Configuration" Uninitialized
Setting:
(03) IO B Overrange Binary Output / (04) IO B Overrange
Current Output / (05) IO B Overrange Current In-/Output / (06)
IO A Overrange Binary Output / (07) IO A Overrange Current
Output / (09) IO A Overrange Current In-/Output
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
22
2222
22
FD_EXTENDED_MAP_
22
R/W Field Diagnostics of "S Electronics" Uninitialized
Setting:
(29) Conv. Zero too large
FD_EXTENDED_MAP_
FD_EXTENDED_MAP_FD_EXTENDED_MAP_
FD_EXTENDED_MAP_
23
2323
23
FD_EXTENDED_MAP_
23
R Field Diagnostics of "S Sensor" Uninitialized
Setting:
(00) Reserved
Parameter
ParameterParameter
Parameter
DD name
Access Description and settings Initial Value