User guide
4 OPERATION
26
UFC 400
www.krohne.com 05/2013 - 4002813701 - AD FF UFC 400 R01 en
FD_SIMULATE
FD_SIMULATEFD_SIMULATE
FD_SIMULATE
Field Diagnostic
Simulate
Used as the field diagnostic condition when the simulation is
enabled.
-
DIAGNOSTIC_
DIAGNOSTIC_DIAGNOSTIC_
DIAGNOSTIC_
SIMULATE_VALUE
SIMULATE_VALUESIMULATE_VALUE
SIMULATE_VALUE
Diagnostic Simulate
Value
R/W Allows the conditions to be manually supplied when
simulation is enabled. The simulate jumper is required for
simulation to be enabled.
Uninitialized
Setting:
(00) Check / (01) Electronics : Operation Info /
(08) Electronics : Power Fail / (10) Configuration : Totaliser /
(11) Process : Signal Unreliable / (12) Process : Signal Lost /
(13) Process : Empty Pipe / (14) Electronics : IO Connection /
(15) Process : Current input / (16) M Process /
(17) M Configuration / (18) M Electronics / (19) M Sensor /
(20) S Process / (21) S Configuration / (22) S Electronics /
(23) S Sensor / (24) C Process / (25) C Configuration /
(26) C Electronics / (27) C Sensor / (28) F Process / (29) F
Configuration / (30) F Electronics / (31) F Sensor
DIAGNOSTIC_VALUE
DIAGNOSTIC_VALUEDIAGNOSTIC_VALUE
DIAGNOSTIC_VALUE
Diagnostic Value
R Current field diagnostic condition. Uninitialized
Setting:
(00) Check / (01) Electronics : Operation Info /
(08) Electronics : Power Fail / (10) Configuration : Totaliser /
(11) Process : Signal Unreliable / (12) Process : Signal Lost /
(13) Process : Empty Pipe / (14) Electronics : IO Connection /
(15) Process : Current input / (16) M Process /
(17) M Configuration / (18) M Electronics / (19) M Sensor /
(20) S Process / (21) S Configuration / (22) S Electronics /
(23) S Sensor / (24) C Process / (25) C Configuration /
(26) C Electronics / (27) C Sensor / (28) F Process / (29) F
Configuration / (30) F Electronics / (31) F Sensor
ENABLE_DISABLE
ENABLE_DISABLEENABLE_DISABLE
ENABLE_DISABLE
Simulate En/Disable
R/W Enable/disable simulation. Uninitialized
Setting:
Uninitialized / Disabled / Active
FD_VER
FD_VERFD_VER
FD_VER
Revision
R The major version of the Field Diagnostics specification used
for the development of this device.
1
FEATURES
FEATURESFEATURES
FEATURES
Features
R Used to shows supported resource block options. Reports
Soft W Lock
MVC Report
Distribution
supported
MVC Publishing/
Subcribing
supported
Multi-bit Alarm
(Bit-Alarm)
Support
Setting:
Reports / Soft W Lock / MVC Report Distribution supported /
MVC Publishing/Subcribing supported / Multi-bit Alarm (Bit-
Alarm) Support
FEATURES_SEL
FEATURES_SELFEATURES_SEL
FEATURES_SEL
Features Selection
R/W Used to select resource block options. Reports
Soft W Lock
Setting:
Reports / Soft W Lock / MVC Report Distribution supported /
MVC Publishing/Subscribing supported / Multi-bit Alarm (Bit-
Alarm) Support
FREE_SPACE
FREE_SPACEFREE_SPACE
FREE_SPACE
Free Space
R Percent of the memory available for further configuration.
Zero in a preconfigured resource.
0.0
Setting:
0.0…100.0
FREE_TIME
FREE_TIMEFREE_TIME
FREE_TIME
Free Time
R Percent of the block processing time that is free to process
additional blocks.
0.0
Setting:
0.0…100.0
Parameter
ParameterParameter
Parameter
DD name
Access Description and settings Initial Value