USB ADAPTER PLUS Quick Start Configuration tool for: • IFC 100 / 300 (with Pactware) • BATCHFLUX 5500 C (with BatchMon Plus) • IFC 010 / 090 / 110 and BATCHFLUX 5012 C / 5015 C (with ImoMon Plus) © KROHNE 06/2014 - 4003748601 - QS USB_Adapter_Plus R03 en
CONTENTS USB ADAPTER PLUS 1 General description 3 2 Operation 4 2.1 2.2 2.3 2.4 IFC 100 .............................................................................................................................. 4 IFC 300 .............................................................................................................................. 5 BATCHFLUX 5500 C .......................................................................................................... 6 Converters with ImoCom...
GENERAL DESCRIPTION 1 USB ADAPTER PLUS The USB-Adapter Plus is an adapter to read / write all kind of data to many different converters.
2 OPERATION USB ADAPTER PLUS As described in the previous chapter, the USB-Adapter Plus can be used in three ways. Each way is described in a separate section. 2.1 IFC 100 The standard delivery includes all items you need to use it with an IFC 100 signal converter. Figure 2-1: Connection of adapter to the GDC bus of the IFC 100.
OPERATION 2 USB ADAPTER PLUS 2.2 IFC 300 The standard delivery includes all items you need to use it with an IFC 300 signal converter. with GDC connection cable Figure 2-2: Connection of adapter to the GDC bus of the IFC 300. 1 Connection room of IFC 300 2 Cable 2x3-pole > 2x4-pole 3 USB-Adapter Plus with IR interface cable Figure 2-3: Connection of adapter to the IR interface of the IFC 300.
2 OPERATION USB ADAPTER PLUS 2.3 BATCHFLUX 5500 C CAUTION! The T-connectors and the cables ( M12 5-pole / 8-pole) are available as an optional package. To order the specific cables notice the items 2 , 3 and 5 in the illustration below Figure 2-4: Connection of adapter to the BATCHFLUX 5500 C.
OPERATION 2 USB ADAPTER PLUS INFORMATION! All relevant tools are on the website of the manufacturer. Installation procedure: • Do NOT connect the USB adapter yet. • Install the software KROHNE BatchMon Setup Version 3.x.x. Ignore any error messages about Windows certificates. • Connect the USB cable to the computer. The wizard "New hardware found" starts. - Choose "Not now", click 1x on "Next". - Screen "Hardware" opens, click 2x on "Continue". - If hardware is detected, click on "Finish".
2 OPERATION USB ADAPTER PLUS Menu C1: Process input No. Function / subfunction Settings / descriptions C1.1 Calibration C1.1 Calibration C1.1.1 Zero calibration Measured zero point (m/s). Use the "calibration" button to calculate a new zero. Calibration procedure takes 30 seconds. C1.1.2 Size entry selection Value (mm), Table (mm, inch) For "Value": manual input of flow meter size in box 1.1.3. For "Table": choose from pull down menu in box 1.1.4. C1.1.
OPERATION 2 USB ADAPTER PLUS C1.2 Filter C1.2 Filter C1.2.1 Min. limitation C1.2.2 Max. limitation -100...-0,001 (m/s) The output freezes at this value. 0,001...100 (m/s) The output freezes at this value. C1.2.3 Flow direction Normal direction (default), Reverse direction C1.2.4 Time constant 0...100 (s) Manual input C1.2.5 Low flow cut off threshold 0...10 (m/s) Manual input C1.2.6 Low flow cut off hysteresis 0...10 (m/s) Manual input C1.3 Information C1.
2 OPERATION USB ADAPTER PLUS No. Function / subfunction Settings / descriptions C2.2.17 Delay low flow cutoff 0...10 [s] Manual input. C2.2 Pulse output (if selected in 2.1.0 "hardware") C2.2.1 Pulse shape Symmetric, Fixed, Automatic (default) C2.2.2 Pulse width 5E-5...2 (s) C2.2.6 Polarity Both polarity, Positive polarity (default), Negative polarity, Absolute polarity C2.2.11 Time constant 0...100 (s) C2.2.12 Invert signal Off (default), On C2.2.13 Max. pulse rate 0,01...
OPERATION 2 USB ADAPTER PLUS Menu C4: Service No. Function / subfunction C4.1 Oscillograph Horizontal axis is the quantity of collected values. Vertical axis is the flow rate in liters per seconde C4.2 Sensor values C4.2.1 Flow velocity C4.2.2 DC voltage electrode 2 C4.2.3 DC voltage electrode 3 C4.2.4 Electronic temperature C4.2.5 Field current settling time C4.2.6 Field current resistance C4.2.7 Status sensor C4.2.8 Status starting phase C4.2.9 Status warnings C4.2.
2 OPERATION USB ADAPTER PLUS 2.4 Converters with ImoCom Old converters can be used if they have an ImoCom connector on board. Some possibilities are shown below. Figure 2-5: 1 2 3 4 5 6 BATCHFLUX 5012 C / 5015 C flowmeter IFC 010 signal converter IFC 090 signal converter IFC 110 signal converter USB-Adapter Plus Optional cable (1x5-pole connector > 2x4-pole connector) CAUTION! • Please note that ".net Framework 2.0" is installed before installation (part of Windows XP service pack 2).
NOTES 3 USB ADAPTER PLUS 06/2014 - 4003748601 - QS USB_Adapter_Plus R03 en www.krohne.
3 NOTES 14 USB ADAPTER PLUS www.krohne.
NOTES 3 USB ADAPTER PLUS 06/2014 - 4003748601 - QS USB_Adapter_Plus R03 en www.krohne.
© KROHNE 06/2014 - 4003748601 - QS USB_Adapter_Plus R03 en - Subject to change without notice. KROHNE product overview • • • • • • • • • • • • Electromagnetic flowmeters Variable area flowmeters Ultrasonic flowmeters Mass flowmeters Vortex flowmeters Flow controllers Level meters Temperature assemblies Pressure transmitters Analysis products Products and systems for the oil & gas industry Measuring systems for the marine industry Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str.