2 OPERATION
10
USB ADAPTER PLUS
www.krohne.com 06/2014 - 4003748601 - QS USB_Adapter_Plus R03 en
Menu C3: Device
C2.2.17 Delay low flow cutoff 0...10 [s]
Manual input.
C2.2 Pulse output (if selected in 2.1.0 "hardware")
C2.2.1 Pulse shape Symmetric, Fixed, Automatic (default)
C2.2.2 Pulse width 5E-5...2 (s)
C2.2.6 Polarity Both polarity, Positive polarity (default), Negative polarity, Absolute polarity
C2.2.11 Time constant 0...100 (s)
C2.2.12 Invert signal Off (default), On
C2.2.13 Max. pulse rate 0,01...10000 (Hz)
C2.2.14 Value per pulse
-1E
+30
...+1E
+30
(m
3
)
C2.2.15 Low flow cut off threshold
-1E
+30
...+1E
+30
(m
3
/s)
Manual input
C2.2.16 Low flow cut off
hysteresis
-1E
+30
...+1E
+30
(m
3
/s)
Manual input
C2.2.17 Delay low flow cutoff 0...10 [s]
Manual input.
C2.3 Status output (not available in BATCHFLUX 5500 C Standard version)
C2.3.1 Mode Off, error, flow direction (default)
C2.3.2 Invert signal Off (default) , on
No. Function / subfunction Settings / descriptions
C3.1 Units
C3.1.1 Volume flow
l/s, l/min, l/h, m
3
/s, m
3
/min, m
3
/h, ft
3
/s, ft
3
/min, ft
3
/h, gal/s, gal/min, gal/h,
lG/min, lG/h, free unit
When you choose "free unit" two additional boxes will appear: box 3.1.2 (text
free unit) and box 3.1.3 (m
3
/s * factor). With this factor the BATCHFLUX will
calculate the right value for your free unit.
C3.1.4 Volume
ml, l, hl, m
3
, in
3
, ft
3
, yd
3
, gal, lG, free unit
When you choose free unit two additional boxes will appear: box 3.1.5 (text
free unit) and box 3.1.6 (m
3
* factor). With this factor the BATCHFLUX will
calculate the right value for your free unit.
C3.1.7 Flow speed ft/s, m/s (default)