Datasheet

159www.kuebler.com© Fritz Kübler GmbH, subject to errors and changes. 10/2016
Hour meters /
Timers
Hour meters / timers, electronic
Codix 134Max. time range 99999 h 59 min or 99999.99 h
Display LCD, 7 digits, 8 mm [0.31“] high
Backlighting external electrical source
24 V DC ±20 %, 50 mA
Modes adding
Display range see next page
Reset manual and electrical
Working temperature -10°C ... +55°C [+14°F ... +131°F]
(non-condensing)
Operating temperature -10°C ... +60°C [+14°F ... +140°F]
(non-condensing)
Storage temperature -20°C ... +70°C [-4°F ... +158°F]
Altitude up to 2000 m [6562‘]
Power supply internal lithium battery
approx. 8 years at 20°C [68°F]
EMC standards EN 55011 class B
EN 61000-6-2, EN 61000-6-3
Device safety designed to EN 61010 part 1
protection class 2
application area pollution level 2
UL approval file E128604
Measuring error per Start/Stop cycle a maximum
error in the order of the smallest
measuring time selected can occur
A. Timer inputs DC versions (max. 30 V DC) INP B
Timer input NPN or PNP
depending on the type (see table)
Switching level NPN LOW: 0 ... 0.7 V DC
HIGH: 3 ... 30 V DC
PNP LOW: 0 ... 0.7 V DC
HIGH: 4 ... 30 V DC
Counting start NPN for LOW signal at the timer input
PNP for
HIGH
signal at the timer input
B. Timer inputs high voltage versions
(10 ... 260 V DC/V AC) INP A
Timer input optocoupler input
Min. pulse time 16 ms
Switching level LOW: 0 ... 2 V DC/V AC
HIGH: 10 ... 260 V DC/V AC
Counting start
for
HIGH
signal at the timer input
C. Time range change (Mode)
Contact input open collector (switching at 0 V)
NPN LOW 0 ... 0.7 V DC
HIGH 3 ... 5 V DC
Time range depending on the circuit
(s. order inform.)
D. Reset input for DC (reset) and High voltage (INPB)
Min. pulse time DC 50 ms
High voltage 16 ms
Contact input DC NPN LOW 0 ... 0.7 V DC
HIGH 3 ... 30 V DC
High voltage input 10 ... 260 V AC/DC
E. Reset locking input (for DC and AC)
Electrical reset key locking
Input not active reset key locked
Contact input open collector NPN
(switching at 0 V)
Switching level NPN LOW 0 ... 0.7 V DC
HIGH 3 ... 5 V DC
General technical data
Technical data
Count input
Electrical characteristics
LCD hour meters
Housing dark grey RAL 7021
Protection IP65 (front side)
Weight approx. 50 g [1.76 oz]
Mechanical characteristics
Transparent cover, lockable, IP65
Sealing cover type K1, IP65
for cut-out 54 x 29 [2.13 x 1.14], for screw mounting to front bezel F1B or
adapter front bezel N003001,
for counters with cut-out 50 x 25 [1.97 x 0.98] or 45 x 22.2 [1.77 x 0.87]
N003002
suitable for front bezel 60 x 50 [2.36 x 1.97], for screw mounting of electromech.
counters and via adapter front bezel N003001 for counters 48 x 24 [1.89 x 0.94] G008301
Adapter front bezel, 72 x 36 [2.83 x 1.42]
Adapter front bezel, 48 x 48 [1.89 x 1.89]
Adapter front bezel, 60 x 50 [2.36 x 1.97]
for cut-out 68 x 33 [2.68 x 1.30] to cut-out 45 x 22.2 [1.77 x 0.87],
for counters 48 x 24 [1.89 x 0.94], as set black and silver anodised 162704 Set
for cut-out 45 x 45 [1.77 x 1.77] to cut-out 45 x 22.2 [1.77 x 0.87],
with clip mounting for counters 48 x 24 [1.89 x 0.94] black T008883
for cut-out 54 x 29 [2.13 x 1.14] to cut-out 45 x 22.2 [1.77 x 0.87],
with screw mounting and gasket for counters 48 x 24 [1.89 x 0.94] black N003001
Mounting frame
with cut-out 50 x 25 [2.36 x 1.97]
via separate adapter also for 45 x 22.2 [1.77 x 0.87]
for snap-on mounting on 35 [1.38] top-hat DIN rail,
for counters 53 x 28 [2.09 x 1.10]
and via separate adapter (T008180) for counters 48 x 24 [1.89 x 0.94] chromated G300004
Accessories Dimensions in mm [inch] Order no.
Suitable gaskets, other accessories and installation examples for optional accessories can be found in chapter accessories or in the accessories section under: www.kuebler.com/accessories.