Datasheet

158
RoHS
IP65
DIN 48 x 24
000000
7 LCDs
12345
00000
PNP/NPN
DC
4 ... 30 V
AC
10...260V
- 10° + 60°
www.kuebler.com © Fritz Kübler GmbH, subject to errors and changes. 03/2013
Order code
Hour meters / timers, electronic
Codix 134Max. time range 99999 h 59 min or 99999.99 h (battery)
a
Backlighting
5 = without
1)
6 = with
b
Count input
Mode INP A: INP B
0 = Timer
1)
0 ... 0.7 V DC NPN
1 = Timer
1)
4 ... 30 V DC PNP
3 = Timer
1)
10 ... 260 V AC/DC AC/DC 10 ... 260 V AC/DC AC/DC
Delivery specification
Timer
Mounting clip
Front bezel for screw mounting (T008181)
56 x 40 mm, panel cut-out 50 x 25 mm
Front bezel for clip mounting (T008180)
53 x 28 mm, panel cut-out 50 x 25 mm
Gasket
Instruction manual, multilingual
1) Stock types
The Codix 134 is a simple battery-powered hour meter for PNP,
NPN and high voltage applications.
Its 7-digit LCD display with optional backlighting can display
various time ranges.
Powerful
High quality LCD display with 8 mm high gures – optional
display backlighting
Time range hours with minutes or industry minutes
1 pulse = 36 sec programmable via control input
Battery lifetime 8 years
High voltage versions for 10 ... 260 V AC/DC voltage pulses, thus
to be connected directly via contactors, relays and motors
Very high accuracy: 100 ppm
Simple
Screw terminals, RM 5 mm
Reset key lockable via the input ‘Reset Enable’
According to version for PNP, NPN switching level or high
voltage version for 10 … 260 V AC/DC switching voltage
Accumulated time is always readable thanks to battery
powering
High protection level IP65
6.134 . 012 . 8 X X
a b
LCD hour meters
Pulse counter/
Totaliser
TimerBattery
powered
Pulse voltage Temperature
range
High protection
level
DIN front bezel LCD display Lockable
reset

Summary of content (3 pages)