User Manual

5
english
Operating instructions
LCD Hour meter
CCOODDIIXX 113344//113355
The Codix 134/135 are battery-powered LCD hour
meters. They can be used for various applications.
Typical uses are for example: operating time and lifeti-
me measurement, passage time measurement, time
monitoring, etc.
They are controlled by means of dry contacts or volta-
ge pulses.
Model Operating
mode
Inputs
INP A INP B
6.134.012.8x0
6.134.012.8x1
6.134.012.8x3
6.135.012.8x0
6.135.012.8x1
6.135.012.8x3
Timer –– 00 ... 0,7 V DC
Timer ––
10 ... 260 V AC/DC
04 ... 30 V DC
10 ... 260 V AC/DC
00 ... 0,7 V DC
04 ... 30 V DC
10 ... 260 V AC/DC
DC operating modes:
Timer: INP A: no function
INP B: Timer-Enable-Input
Timer: INP A: Timer-Enable-Input AC/DC
INP B: reset input AC/DC
AC operating modes:
Table 1
Time range
99999h 59 m/
99999.99 h
9999 h 59 m 59 s/
9999999.9 s
10 ... 260 V AC/DC
NPN
PNP
AC/DC
NPN
PNP
AC/DC
AC/DC
AC/DC
Options: x = 5: no backlight
x = 6: with backlight
Main technical features:
Display: LCD, 8 decades, height of the figures 8 mm
Display range:
0 ... 99999999 with leading zeros
suppression.
Accuracy: < 100 ppm
Overflow:
In case of a display range overflow, the
timer starts again from 0, but without remo-
ving the leading zeros and activating all
decimal points.
Keys: Electrical locking of the reset key
Housing: Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
22,2
+0,3
x 45
+0,6
mm
Mounting depth:
approximately 48 mm
Weight: approximately 50 g
Protection level:
IP65 on the front side
Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: 4,0 mm
2
single-wire
2,5 mm
2
thin wire AWG 12
Connection diameter:
0,4 ... 2,3 mm single-wire
AWG 28-12
EMC: Interference emissions EN55011 Class B
Interference resistance EN 61000-6-2
Low Voltage Directive (for the AC models):
EN 61010 Part 1 ; overvoltage category 2,
contamination level 2
Power supply:
Non-replaceable lithium battery
(lifetime approximately. 8 years at 20°C)
Working temperature:
–10 ... +55 °C, relative humidity < 85%,
without condensation
Operating temperature:
–10 ... +60 °C
Storage temperature:
–20 .. +70°C
Backlighting:
must be powered by an external elecrical
source (24 V ±20%, 50 mA)