Datasheet
554
RoHS
IP69k
-40°
...
+85°C
1.4404
V4A
www.kuebler.com © Fritz Kübler GmbH, subject to errors and changes. 10/2017
Linear measuring technology
Wide tempera-
turerange
High protection
level
Robust
• Protection level up to IP69k and wide temperature range from
-40°C ... +85°C.
• The titanium-anodized aluminum housing and the stainless
steel wires allow using the mechanics even in harsh conditions.
• Wire diameter (stainless steel, V4A) up to ø 1.5 mm - ideal for
outdoor applications.
Versatile
• Measuring length up to 10 m.
• Redundant outputs (mA, V, R, CANopen).
• The right measuring wire and the right wire fastening for every
application.
• Linearity up to ±0.1 % of the measuring range.
• Various constructions: open, closed housing or housing with
perforated sheet steel cover.
Long service
life
Measuring length up to 10 m
Linearity up to ±0.1 %Draw wire encoder D120
Draw wire mechanics
for outdoor applications
Their extremely robust construction, their high IP69k protection
level and their wide temperature range make these new draw
wire encoders particularly reliable and durable. Their flexibility
and adaptability reflects in the wide range of housing and wire
types, the long measuring range and the various interfaces.
The possibility of redundancy must be particularly pointed out.
Standard variants are represented bold underlined
Order code
D8.D120
Type
. X X X X . .XXXX 0000
a b c d e f
1) Wire type availability depends on the selected measuring range, refer to the technical data.
2) In preparation, samples available Q4/2017, series availability planed for Q1/2018.
3) Other cable length on request.
a
Measuring length
3 = 3 m
4 = 4 m
5 = 5 m
6 = 6 m
7 = 7 m
8 = 8 m
9 = 9 m
A = 10 m
b
Wire types
1)
1 = V4A, ø 0.5 mm
2 = V4A, ø 1.0 mm (measuring length 3 ... 8 m)
3 = V4A, ø 1.5 mm (measuring length 3 ... 6 m)
c
Linearity
1 = 0.5 %
2 = 0.25 %
3 = 0.1 %
d
Housing
1 = open housing, open wire guide
3 = housing with perforated sheet metal cover,
open wire guide
4 = housing with perforated sheet metal cover,
closed wire guide
6 = closed housing, closed wire guide
e
Sensor type
A11 = 4 ... 20 mA / 12 ... 30 VDC
A22 = 0 ... 10 V / 12 ... 30 VDC
A33 = 1 kΩ / max. 30 VDC
CC1 = CANopen
2)
R11 = 2 x 4 ... 20 mA / 12 ... 30 VDC
R22 = 2 x 0 ... 10 V / 12 ... 30 VDC
R33 = 2 x 1 kΩ / max. 30 V
RC1 = 2 x CANopen
2)
f
Type of connection / protection level sensor
1 = radial cable, 2 m [6.56‘] TPE / IP69k
3)
3 = radial M12 connector / IP67
4-pin for sensor type A11 ... A33
8-pin for sensor type R11 ... R33
Redundancy V4A