Refrigerator User Manual

RS-35G swinging bucket rotor
16x2mL 9.5∼11.0x36∼42 15,000 18,360 053-5130
4x0.5mL 7.0∼7.9x25∼34 15,000 16,100 053-5130
20x0.5mL 7.0∼7.9x25∼34 15,000 16,100 053-5140
36x0.4mL 5.4∼6.1x26∼48 15,000 18,360 053-5150
16x0.2mL PCR 5.9∼6.3x20∼24 15,000 11,820 053-5130 055-0500
RA-159G
72x2mL 9.5∼11.0x36∼42 13,500 24,250
72x0.5mL 7.0∼7.9x25∼34 13,500 24,040 055-7590
72x0.4mL 5.4∼6.1x26∼48 13,500 23,640 055-7580
72x0.2mL PCR 5.9∼6.3x20∼24 13,500 20,580 055-0500
44,370
45,100
36,190
41,240
34,900
28,710
2,270
Micro Rotor
Swinging Bucket Rotor
AG-224
24x2mL 9.5∼11.0x36∼42 22,000 44,370
24x0.5mL 7.0∼7.9x25∼34 22,000 39,500 055-7590
24x0.4mL 5.4∼6.1x26∼48 22,000 43,830 055-7580
24x0.2mL PCR 5.9∼6.3x20∼24 15,000 16,100 055-0500
*3
*3
*1
*1
*1
*1
g the sample
RS-1400GA
4x250/350mL 67∼71x100∼128 5,000/4,000 4,810/3,080
RS-200G
4x50mL 28.7∼29x103∼109 11,500 20,700
48x2mL 10.7x42 5,000 4,160
attached to rotor S17008
48x5mL RIA tube 12.5x55∼75 5,000 4,160 attached to rotor S17006
48x7mL 12∼12.5x100∼112 5,000 4,160 attached to rotor S17007
28x7mL blood collecting tube 12.5∼13x75∼106 5,000 4,160 attached to rotor S17027
12x15mL Conical tube 16.5x120.6 5,000 4,160 attached to rotor S17019
12x15mL Conical tube 16.5x120.6 5,000 4,470 S13130
28x10mL blood collecting tube/15mL
15.5∼17x87∼110 5,000 4,160 attached to rotor S17015
4x50mL 34x110 5,000 4,160
attached to rotor S17050
4x50mL 27∼35.8x82∼110 5,000 4,160 attached to rotor 055-5670
4x50mL Conical tube 29.5x117 5,000 4,160 attached to rotor S17049
4x100mL 44∼45x110 5,000 4,160
attached to rotor S17100
4x200mL 56.5x104 5,000 4,160 attached to rotor
80x2mL 9.5∼11x36∼42 3,500 2,290 053-5820 055-4800
96x6mL RIA tube 10∼12.3x65∼95 3,500 2,190 053-5820 055-4730
80x10mL 12.5∼13.8x65∼95 3,500 2,260 053-5820 055-4740
4
8x10mL blood collecting tube/15mL
15∼17.2x81∼110 3,500 2,330 053-5820 055-4750
68x5/7mL blood collecting tube
12.5∼13.7x62∼110 3,500 2,300 053-5840 055-0260
6
8x10mL blood collecting tube/15mL
15∼17.2x52∼110 3,500 2,300 053-5840
28x15mL Conical tube 17x121 3,500 2,300 053-5840
32x15mL Conical tube 17x121 3,500 2,330 053-5820 055-4780
8x50mL 27∼36.4x85∼110 3,500 2,330 053-5820 055-4760
16x50mL Conical tube 30x117 3,500 2,330 053-5820 055-6070
4x100mL 38∼46.5x75∼120 3,500 2,330 053-5820 055-4770
4x175mL Conical tube 61x118 3,500 2,330 053-5820 055-4850
4x200mL Conical tube 61x130 3,500 2,330 053-5820 055-4850
4x225mL Conical tube 61x137 3,500 2,330 053-5820 055-4850
4x250mL 60∼61.8x100∼130 3,500 2.380 053-5820 055-4850
RS-410G
RS-720G
1 The RCF figure shows RCF of the outer tube.
As to RCF of the inside, please contact your local dealer.
2 Sealing cap and sealing adaptor for bio-hazard proof are available. Please contact
your dealer for details.
3 Please confirm the delivery schedule with your dealer.
4 RS-410G can accommodate sealing cap (Code No.S17111) (optional).
5 S17019 tube rack cannot be accommodated with the sealing cap. Code No.S13130
12x15 mL conical bucket can accommodate sealing cap (Code No.S17111) (optional).
6 175 mL conical tube is made by Falcon (Catalog No.352076) and requires a cushion (Catalog No.352090).
200 mL conical tube is made by Nalge Nunc (Catalog No. 376813) and requires a cushion
(Catalog No.377585).
225 mL conical tube is made by Falcon (Catalog No.352075) and requires a cushion (Catalog No.352090).
7 Please check the strength of plates before using the centrifuge. The plate at the bottom may be damaged.
8 As to RCF display, please refer to Instruction and Service manual.
9INSEPACK II 5/7 mL of Sekisui, VENOJECT II 5/7 mL of Terumo, NEOTUBE 5/7 mL of Nipro and
VACUTAINER 5/7 mL of Beckton Dickenson can be used.
Sealing cap is available and is biohazard-proof. Autoclavable (121°C)
*3
*3,4
*3
*5
*5
*9
*8
*8
*8
*8
*6,8
*6,8
*6,8
g 4℃
Max. RCF
×g
Tube Rack
Tube size Max. Speed Max. RCF Bucket
Adaptor
diam. x length mm rpm xg Code No.
Code No.
Tube adaptor is available for various capacities.
As for details, please contact your dealer.
7780-8P英 05.5.25 11:37 AM ページ2