Installation Instructions
8 HYDRAULIC
SYSTEM
81700'82100·82400 WSM, 11772
(3) Nuts
(1) Spool
(2) Lever
8193P810
8193F814
0
(2) Disassembling Position Control Valve
Spool
1.
Remove the nuts (3).
2. Draw
out
the spool (1)
with
the lever (2).
III IMPORTANT
• Measure the length (A)
before
disassembling,
and make
sure
to
reset
it
when
reassembling.
(Reference)
• When the poppet 2
is
completely closed,
the
distance (B)
between valve body and
nut
becomes approximately 32.3
to
32.5 mm (1.27
to
1.28 in.).
Plunger
1. Remove the plug 4 (1), and
draw
out
the
plunger
(2) and
spring
(3) from the spool (4).
(When reassembling)
• Take care
not
to
damage
the
O-ring.
7.85
to
11.77 N'm
Tightening
torque
Plug 4 0.8
to
1.2
kgf'm
5.79
to
8.68 ft-Ibs
8193P811
(1) Plug 4
(2) Plunger
(3) Spring
(4) Spool
3
Poppet 1
1.
Remove the plug 1 (3), and
draw
out
the
poppet
1
(2)
and
spring
(1).
(When reassembling)
• Take care
not
to
damage
the
O-ring.
29.4
to
49.0 N'm
Tightening
torque
Plug 1 3.0
to
5.0
kgf·m
21.7
to
36.2 ft-Ibs
8193P812
(1) Spring
(2) Poppet 1
(3)
Plug 1
E8-S6