Installation Instructions

B1700·B2100·B2400 WSM,11770
TROUBLESHOOTING
8 HYDRAULIC
5Y5TEM
Symptom
Probable Cause Solution
Reference
Page
Implement
Does
Control valve broken
Replace
8-510
Not
Rise
Control valve
improperly
adjusted
Adjust
8-511
(No Noise)
Control valve
improperly
assembled
Assemble
8-511
Relief valve spring damaged
Replace
8-511
5pool sticks
Repair
8-511
Piston O-ring
or
cylinder damaged
Replace
8-510
(Noise)
Oil strainer clogged
Clean
or
Replace
-
5uction pipe loosen
or
broken
Repair
or
Replace
-
5uction pipe connecting hose loosen
or
Repair
or
Replace
-
broken
5uction pipe O-ring broken
Replace
-
Insufficienttransmission oil
Refill
G-8
Relief valve setting pressure
too
low
Adjust.or Replace
8-58
Hydraulic
pump
broken
Replace
8-56
Implement
Does
Feedback rod
improperly
adjusted
Adjust
8-58
Not
Reach
Maximum
Height
Implement
Does
Control valve
malfunctioning
Repair
or
Replace
8-510
Not
Lower
Implement
Drops
by
Hydrau Iic cyli nder
worn
or
damaged
Replace
8-510
Its
Weight
Piston O-ring
worn
or
damaged
Replace
8-510
Control valve
malfunctioning
Replace
8-510
Implement
Hunts
Control valve
improperly
adjusted
Adjust
8-511
8-51