Operation Manual
BX25, RCK54(P)-23BX, RCK60B-23BX,
lA240,
BT601, WSM
TRANSAXLE
Check and High Pressure Relief Valve Plug
1.
Remove the check and high pressure relief plug (G 1/2).
(When reassembling)
(1
lightening
torque
Check and high pressure
relief valve plug
(G
1/2)
59 to 78 N'm
6.0 to 8.0 kgf'm
44 to 571bHt
(2)
(1) \ .
"".
(4)
~\~,
.
(3)
3TAAAAIKPOO7
A
(1) Center Section (3) Plug
(2) Plug
W1087469
Check and High Pressure Relief Valve
1.
After removing the plug (1), draw out the spring (3) and the check
and high pressure relief valve assembly (4) (5).
(When reassembling)
• Take care not to damage the O-ring (2) on the plug (1).
• Since there is an orifice (1.5 mm, 0.059 in.) in the check and relief
valve body (reverse) (5), re-install the check and relief valve (4)
(5) to their original positions.
(1) Plug
(4) Check and Relief Valve (Forward)
(2) O-ring (5) Check and Relief Valve (Reverse)
(3) Spring
W1087625
2-S25