Operation Manual
BX25. RCK54(P)-23BX. RCK60B-23BX. LA240.
BT601,
WSM
G GENERAL
[2]
BATTERY
3TMABABOPOO6B
[3]
FUSE
3TMABABOP014A
(2)
[4]
CONNECTOR
(A)
3TMABABOP015A
o Take care not to confuse positive and negative terminal posts.
o When removing battery cables, disconnect negative cable first.
When installing battery cables, check for polarity and connect
positive cable first.
• Do not install any battery with capacity other than is specified
(Ah).
• After connecting cables to battery terminal posts, apply high
temperature grease to them and securely install terminal covers
on them.
• Do not allow dirt and dust to collect on battery.
A CAUTION
• Take care
not
to
let battery
liquid
spill
on
your
skin
and
clothes.
If
contaminated, wash
it
off
with
water immediately.
• Before recharging the battery, remove
it
from
the machine.
• Before recharging, remove cell caps.
• Do recharging in a well-ventilated place where there
is
no
open flame nearby, as hydrogen gas and oxygen are formed.
W10118160
o Use fuses with specified capacity.
Neither too large or small capacity fuse is acceptable.
o Never use steel or copper wire
in
place
of
fuse.
o Do not install working light. radio set. etc. on machine which is not
provided with reserve power supply.
• Do not install accessories
if
fuse capacity of reserve power
supply
is
exceeded.
(1) Fuse (2) Slow Blow Fuse
W10120920
• For connector with lock, push lock to separate.
(A) Push
W10122110
•
In
separating connectors, do not pull wire harnesses.
• Hold connector bodies to separate.
(8)
(A)
Correct
(8)
Incorrect
W10122720
3TMABABOP016A
G-5