Operation Manual
BX25,
RCK54(P)-23BX,
RCK60B-23BX,
LA240,
BT601,
WSM
HYDRAULIC SYSTEM
1.
TROUBLESHOOTING
Symptom
Implement Does Not
Rise (No Noise)
Implement Does Not
Rise (Noise)
Probable Cause
Control valve broken
Solution
Replace
Reference
Page
5-513
Control valve improperly assembled
Relief valve spring damaged
Spool sticks
Piston O-ring
or
cylinder damaged
Oil filter cartridge clogged
Repair
Replace
Repair
Replace
Replace
5-513
5-54
5-S13
5-S14
G-13
i
I
Suction pipe loosen
or
broken
Suction pipe connecting hose loosen
or
broken
Suction pipe O-ring broken
Insufficient transmission oil
Relief valve setting pressure too low
Repair or replace
Repair or replace
Replace
Refill
Adjust
or
replace
-
-
G-13
5-S4
i
Hydraulic pump broken Replace 5-S12
Implement Does Not
Lower
Control valve malfunctioning Repair or replace 5-S13
Implement Drops by
Its Weight
Hydraulic cylinder worn or damaged Replace 5-S13
Piston O-ring worn
or
damaged Replace 5-514
Control valve malfunctioning Replace 5-S13
W1014322
5-S1