Operation Manual
BX25, RCK54(P)-23BX, RCK60B-23BX, LA240, BT601, WSM
ELECTRICAL SYSTEM
2.
STARTING SYSTEM
[1]
MAIN SWITCH POSITION
(18)
(12)
20RW
OFF
S10
ON
RUN
GLOW
STAAT
(1
)
i''''''5A~
16RW
(7)
3TAAAAF9P038A
(1) Fuse
(2)
Seat
(3) Seat Turn Over
(4) R-PTO
(5) PTO
20
Y
a:
N
50A
(13)
:?CB
:?CRY
(14)
(15)
(6)
HST
Neutral
(7) Main Switch
(8) Slow Blow Fuse
(9) Starter Motor
(10) Battery
(11) Alternator
(12) Glow Lamp
(13) TImer Relay
(14) Frame Earth
(15) Fuel Pump
(16) Solenoid
(17) Glow Plug
(18) OPC TImer
When the main switch (7) is turned to the
GLOW
position, the terminal BAT is connected to the terminal ON and
AC. The glow plugs (17) become red-hot, and the preheat indicator lamp also lights on while preheating.
When the main switch
is
then turned to the
START
position with the safety switches on, the terminal BAT is
connected to the terminals
GLOW
and ST. Consequently, battery (10) current flows to the starter motor (9) and start
the engine.
The main switch automatically returns to the
ON position, the terminal BAT
is
connected only to the terminal
GLOW, thereby causing the starting circuit to
be
opened, stopping the starter motor.
When the main switch turned from the
ON position to the
OFF
position, the fuel cut-off solenoid moves the fuel
injection pump control rack to the
"No Fuel
Injection"
position and stops the engine.
The BX25 tractor (with the OPC timer (18))equipped the operator presence control (OPC) system which
automatically stops the engine
in
approximately one second when operator stands from the seat while shifting the PTO
clutch lever
and
range gear shift lever
6-M3