Operation Manual
BX25, RCK54(P)-23BX, RCK60B-23BX, LA240, BT601, WSM
ELECTRICAL SYSTEM
(7) T
.J..
(6)
(2) (3)
(4)
(5)
Checking OPC Timer
1.
Remove the OPC timer. (The OPC timer
is
located under the
fender center stay.)
2.
Connect the jumper leads across the battery terminal and the
Red
I White terminal (2), and across the battery positive terminal
and the Yellow terminal (3).
3.
Connect the jumper lead across the battery negative terminal and
the Black terminal (5), and across the battery negative terminal
and the Blue terminal.
4. Connect the jumper lead across the Red terminal (4) and the bulb
terminal.
5.
The bulb lights up when disconnecting the jumper lead from the
Red
I White terminal (2) 0.7 to 1.3 seconds, the OPC timer (1) is
proper.
(1) OPC Timer (5) Black Terminal (To Frame Earth)
(2) Red I White Terminal (From Battery) (6) Bulb (Load)
(3) Yellow Terminal (From
OPC
Switch) (7) Battery
(4) Red Terminal
(To
Key Stop Solenoid)
W10647550
3TAAAAF9P044A
6-814