Operation Manual

BX25, RCK54(P}-23BX, RCK60B-23BX. LA240. BT601, WSM
ELECTRICAL
SYSTEM
3TAAAAF9P027E
5)
Turn Signal
Light
Switch Continuity when Setting Switch
Knob "RIGHT" Position
1.
Set the turn signal switch knob to the RIGHT position.
2.
Measure the resistance with an ohmmeter across the green lead
(1) and red
I white lead (2), and across to the green lead (1) and
green
I white lead (3).
3.
If 0 n is not indicated, the combination switch is faulty.
Green lead (1) -
Red
I
on
Resistance
White lead (4)
(Switch knob at RIGHT
Green lead (1)
position)
Infinity
Green
I White lead (3)
(1) Green Lead
A : Turn Signal
light
Switch "RIGHT"
(2)
Red
I White Lead Position
(3) Green
I White Lead
W1052995
6)
Turn Signal
Light
Switch Continuity when Setting Switch
Knob
"LEFT" Position
1.
Set the turn signal switch knob to the LEFT position.
2. Measure the resistance with an ohmmeter across the green lead
(1) and red
I white lead (2), and across to the green lead (1) and
green
I white lead (3).
3.
If 0 n is not indicated, the combination switch is faulty.
Resistance
Green lead (1) -
Red
I
White
lead (4)
Infinity
(Switch knob at LEFT
position)
Green lead
(1)-
Green I White lead (3)
on
(1) Green
Lead
A : Turn Signal
Light
Switch
"LEFT"
(2) Red I White Lead
Position
(3) Green
I White Lead
W1053450
6-S20