Operation Manual
BX25, RCK54(P)-23BX, RCK60B-23BX, LA240, BT601, WSM
ELECTRICAL SYSTEM
3TAAAAF9P027G
3TAAAAF9P027H
7) Hazard
Switch
Continuity
when
Setting
Switch
Knob
at
"OFF"
Position
1.
Set the hazard switch knob to the OFF position.
2. Measure the resistance with an ohmmeter across the black
I blue
lead (1) and blue
I white lead (2).
3.
If infinity is not indicated, the combination switch is fautty.
Resistance
(Hazard switch at OFF
position)
Black
I Blue lead (1) -
Blue
I White lead (2)
Infinity
(1) Black
I Blue Lead
A : Hazard
Switch "OFF" Position
(2) Blue
I White Lead
W1053841
8} Hazard
Switch
Knob
at
"ON"
Position
1.
Set the hazard switch knob to the ON position.
2.
Measure the resistance with an ohmmeter across the black / blue
lead (1) and blue
I white lead (2).
3. If 0
n is not indicated, the combination switch is faulty.
Resistance
(Hazard switch at
ON
position)
Black
I Blue lead
(1)-
Blue I White lead (2)
on
(1) Black I Blue Lead
A:
Hazard Switch
"ON"
Position
(2) Blue
I White Lead
W1054637
6-521