Operation Manual
BX25, RCK54(P)-23BX, RCK60B-23BX, LA240, BT601, WSM
G GENERAL
Checking Battery
Condition
(Continued)
• Battery
for
storage
1.
When storing the tractor for a long period, remove the battery
from tractor, adjust the electrolyte to the proper level and store in
a dry place out
of
direct sunlight.
2.
The battery self-discharges while it is stored.
Recharge it once every three months
in
hot seasons and once
every six months
in
cold seasons.
3.
(For non-accessible maintenance-free type batteries.)
Maintenance-free, non-accessible batteries are designed to
eliminate the need to add water. Yet the volume
of
electrolyte
above plates may eventually become depleted due to abnormal
conditions such as high heat
or
improper regulator setting. Use
a voltmeter to check the state
of
change. (See reference chart
below to determine
if
charging
is
necessary.)
Battery voltage
Reference state
of
charge
12.6
100 % (Full charge)
12.4
75%
12.2
50%
12.0
25%
11.8
0%
W1033625
Cleaning
Air
Cleaner Element
A CAUTION
• Be sure
to
stop
the engine and remove
the
key before
cleaning
air
cleaner element.
1.
Remove the air cleaner cover (2) and the element (1).
- Undo the hook.
- Turn the cover clockwise and detach it.
2.
Clean the element:
- When dry dust adheres to the element, blow compressed air
from the inside, turning the element. Pressure
of
compressed
air must be under 205 kPa
(2.1
kgf/cm
2
,
30 psi).
- When carbon or oil adheres to the element, soak the element
in detergent for 15 minutes then wash it several times in water,
rinse with clean water and dry it naturally. After element is fully
dried, inspect inside
of
the element with a light and check if it
is
damaged or not. (referring to the instructions
on
the label
attached to the case.)
3.
Replace air cleaner element:
Once yearly
or
after every sixth cleaning, whichever comes first.
• NOTE
• Check
to
see
if
the evacuator valve
is
blocked
with
dust.
• IMPORTANT
• The
air
cleaner uses a
dry
element, never
apply
oil.
• Do
not
run the engine
with
filter
element removed,
•
Align
the
arrow
marks
when
reinstalling
the
cover.
If
the
cover
is
improperly
fitted,
dust
passes
by
the baffle and
directly
adheres
to
the element.
• Evacuator Valve
Open the evacuator valve once a week under ordinary conditions
or daily when used
in
a dusty place to get rid
of
large particles
of
dust
and dirt.
(1) Element
(3) Evacuator Valve
(2) Cover
W1017166
G-18