Operation Manual

BX25,
RCK54(P)-23BX,
RCK60B-23BX,
LA240,
8T601,
WSM
ELECTRICAL SYSTEM
Brush Holder
1.
Check the continuity across the brush holder and the holder
support with
an
ohmmeter.
2.
If
it conducts, replace the brush holder.
W1017672
3EEABAB1P189A
i 3EEABAB1 P186A
Armature Coil
1.
Check the continuity across the commutator and armature coil
core with an ohmmeter.
2.
If it conducts, replace the armature.
3.
Check the continuity across the segments
of
the commutator with
an
ohmmeter.
4.
If it does not conduct, replace the armature.
W1017767
3EEABAB1 P190A
Field Coil
1.
Check the continuity across the lead (1) and brush (2) with an
ohmmeter.
2.
If it does not conduct, replace the yoke assembly.
3.
Check the continuity across the brush (2) and yoke (3) with
an
ohmmeter.
4.
If it conducts, replace the yoke assembly.
(1) Lead
(3) Yoke
(2) Brush
W1018015
3EEABAB1P191A
6-S29