Operation Manual
BX25,
RCK54(P)-23BX,
RCK60B-23BX,
LA240,
BT601,
WSM
G GENERAL
Flushing Cooling System and Changing Coolant
A CAUTION
• Be sure
to
stop
the engine and remove the key before
checking
coolant
level.
• Do
not
remove
the
radiator cap when
the
engine is hot. Then
loosen cap
slightly
to
the
stop
to
relieve any excess
pressure before removing cap completely.
1.
Stop the engine, remove the key and let cool down.
2.
To drain the coolant, open the radiator drain plug, and remove
radiator cap. The radiator cap must be removed to completely
drain the coolant.
3.
After all coolant is drained, close the drain plug.
4. Fill with clean water and cooling system cleaner.
5.
Follow directions
of
the cleaner instruction.
6.
After flushing, fill with clean water and anti-freeze until the coolant
level is just below the radiator cap.
Install the radiator cap securely.
7.
Fill with coolant up
to
"H"
mark on the recovery tank.
8.
Start and operate the engine for few minutes.
9.
Stop the engine, remove the key and let cool.
1 a.Check coolant level
of
recovery tank and add coolant if
necessary.
11.Properly dispose
of
used coolant.
• IMPORTANT
• Do
not
start engine
without
coolant.
• Use clean, fresh water and anti-freeze
to
fill the radiator.
• When
the
anti-freeze
is
mixed with water,
the
anti-freeze
mixing
ratio
must
be less than
50
%.
• Securely tighten radiator cap.
If
the cap is loose
or
improperly fitted, water may leak
out
and
the
engine could
overheat.
3.1L
Coolant capacity (with recovery tank) 3.3 U.S.qts
2.7Imp.qts
(1) Radiator Cap (2) Drain Plug
W1021307
G-27