G-28
03-M-E3B, 03-M-DI-E3B, 03-M-E3BG WSM
G GENERAL
[12] CHECK POINTS OF EVERY 1500 HOURS
CAUTION
• Check the injection pressure and condition after confirming that there is nobody standing in the direction
the fume goes.
• If the fume from the nozzle directly contacts the human body, cells may be destroyed and blood poisoning
may be caused.
Nozzle Spraying Condition
[D1503-M, D1703-M, D1803-M, V2003-M, V2203-M, V2403-M,
V2403-M-T]
[D1703-M-BG, V2003-M-BG, V2003-M-T-BG, V2203-M-BG,
V2403-M-BG]
1. Set the injection nozzle to a nozzle tester, and check the nozzle
spraying condition.
2. If the spraying condition is defective, replace the nozzle piece.
W10411400
[D1803-M-DI, V2403-M-DI, V2403-M-DI-T]
1. Set the injection nozzle to a nozzle tester, and check the nozzle
spraying condition.
2. If the spraying condition is defective, replace the injection nozzle
assembly.
W1037040
(a) Good (b) Bad
(a) Good (b) Bad