OPERATOR'S MANUAL
Table Of Contents
- OPS - Excavator U48-4 (RD45881312)
- Abbreviation List
- General Symbols
- Foreword
- Safety First
- Contents Page
- Safe Operation
- Dealer Service
- Technical Data
- Description of Machine Parts
- Instrument Panel and Control Elements
- Checks Before Start
- Daily Checks
- Checking the Devices
- Starter Switch
- Display Selector Switch
- LCD Display for Normal Operation
- Warning Lamp
- LCD Display for Warning
- Setting the Clock
- Reordering the year/month/day and Changing the AM/PM System to the 24 hour one
- Log Record
- Periodic Check
- If all the Check Points are not Displayed at a Glance on a Single Screen
- When the Checkup is Completed
- Horn Switch
- Working Light Switch
- AUX Port Flow Rate Limit Switch
- Auto Idle Switch
- Throttle Potentiometer
- Travel Speed Switch
- CAB Type Machines
- Air Conditioner
- Handling the Safety Devices
- Operation of the Engine
- Excavator Operation
- Running-In of the New Excavator
- Starting
- Driving
- Turns
- Up and Downhill Driving
- Parking on a Slope
- Operation of the Dozer
- Two Pattern Selection System (TPSS)
- Operation of the Boom
- Operation of the Arm
- Operation of the Bucket
- Unit Swing and Boom Swing Operation
- Auxiliary Port Operation
- How to Release Pressure Trapped in the Hydraulic System
- 1 Way or 2 Way Circuit Selection Valve Operation
- Auto Idle (AI) Operation
- Important Information on Excavator Operation
- Transporting the Excavator on a Vehicle
- Lifting of the Excavator
- Maintenance
- Maintenance Intervals
- Opening and Closing of Covers
- Daily Checks
- Checking Coolant Level
- Checking Fuel Level
- Checking Engine Oil Level
- Checking Hydraulic Oil Level
- Checking V-Belt
- Checking Radiator and Oil Cooler
- Checking Washer Liquid
- Cleaning Pre-Cleaner
- Checking and Cleaning Engine and Electrical Wiring
- Greasing Boom Swing Fulcrum
- Washing Whole Machine
- Greasing Front Attachments (without Bucket Pin and Boom Swing Fulcrum)
- Greasing Bucket Pin and Bucket Link Pin
- Regular Checks and Maintenance Work
- Other Adjustments and Replacements
- Troubleshooting
- Operation Under Cold Weather Conditions
- Long Storage
- Recommended Oils
- Appendices
- Lifting Capacity
- List of Screens
43EXCAVATOR OPERATION
7. Press the switch 2 or 3 to preset the maximum flow
volume.
Set the bar to the highest level, and the flow volume
will be maximized.
Set the bar to the lowest level (no bar displayed), and
there will be no oil flow.
Then press the switch 4 to go to the next port, and
make the settings for all the other ports.
A Some attachments might not be activated even when
the bar level is still somewhat above the lowest
position. Or even when the bars of ports 1 and 2 (or of
ports 3 and 4) are at the same level, the same speed
might not be achieved. This does not indicate a
machine problem, however. Readjust the bar to the
optimum level according to your attachment manual.
A Suppose that the same attachment is mounted on
another machine. Even if the same flow control setting
is made, the same speed cannot be achieved. Make
an optimum setting on each machine.
8. Go back to Step 3 to make settings for the next action
mode. When all the settings of all the action modes
have been made, press the switch 1 to return to the
normal screen.
C AUX port MAX. Flow volume
A When the AUX port is not used for a long period, dirt
particles can settle in the lower part of the AUX port
lines. When the plugs on the AUX port lines are
removed to connect attachments, drain approx. 100 cc
(3.4 oz) of oil before making connections.
(1) Switch 2 (Higher flow volume)
(2) Switch 3 (Lower flow volume)
(3) Switch 4
(A) "MAX. flow volume"
(B) "Output interrupted"
(1) Switch 1
AUX 1 port AUX 2 port
MAX. flow volume
(Theoretical L/min)
75
(20)
37
(9.87)
MAX. pressure
MPa (kgf/cm ) [psi]
17.2
(175)
[2500]
17.2
(175)
[2500]