Full Product Manual
19
burns. If a cabinet storage is to be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5" (12.7cm) beyond the boom of the
cabinets.
Connect Range to Gas Supply
1. Install a manual gas line shut-off valve in the gas line in an easily accessed locaon
outside the range in the gas piping external to the appliance for the purpose of turning
on or shung off gas to the appliance.
2. Install male
1
/
2
inch flare union adapter to
1
/
2
inch NPT internal thread elbow at inlet
of regulator. On models equipped with standard twin burners, install the male pipe
thread end of the
1
/
2
inch flare union adapter to the
1
/
2
inch NPT internal thread at inlet
of pressure regulator. Use a wrench on the regulator fing to avoid damage.
3. Install male
1
/
2
inch or
3
/
4
inch flare union adapter to the NPT internal thread of the
manual shut-off valve, taking care to secure the shut-off valve to keep it from turning.
4. The gas supply pressure for checking the regulator seng is 6 in.w.c. (Nature Gas) and
11 inch.w.c. (LP gas) connect flexible gas line connector to the regulator on the range.
Posion range to permit connecon at the shut-off valve.
When all connecons have been made, make sure all range controls are in the posion
and turn on main gas supply valve.
5. Leak tesng
of the appliance shall be conducted according to the manufacturer’s
instrucons. Use some soap water (50% water and 50% soap) or a leak detector at all
joints and connecons to check for leaks in the system. Do not use a flame to check for
gas leaks.
FOR MORE DETAILS AND INFORMATION, PLEASE VISIT OUR WEBSITE
WWW.KUCHT.COM