DS203 USER’S MANUAL
Contents I Product Intro………………………………………………………………………………………..…….2 II General Safety Rules ……………………………………………………………………………….. 2 III Major Functions ……………………………………………………………………………………..2 IV Operation Precautions …………………………………………………………………………………..2 V General Inspection …………………………………………………………………………………. 3 VI Functional Inspection................................................................................................................................ 3 VII Firmware Upgrade …………………………………………………………………………………….
I Product Intro DS203 is a 5-trace 4-channel digital oscilloscope for common electronic engineering tasks. Its CPU is based on ARM Cortex M3, adopting FPGA to manage the control & data buffering of ADC. A built-in 2MB USB disk enables users to store waveforms & upgrade firmware. It also provides 4 application areas, convenient for users to load & upgrade at most 4 kinds of application firmware.
V General Inspection When you get a new DS203 oscilloscope, it’s suggested to inspect the product by following steps. 1.Inspect for damage caused by shipping. If the packaging carton or protection pad is seriously damaged, keep the package until you check the oscilloscope & accessories electrically and mechanically.
VIII Oscilloscope Familiarization 1. Interfaces & buttons. Front view, left→right: RUN/HOLD(||), CALIBRATE (■), PRESET (●), SAVE WAVE(▲)、 NAVIGATOR A(―…+), NAVIGATOR B(…). Left view, top→bottom:Wave output[WAVE OUT],analog channel B[CH_B], analog channel A[CH_A]. Right view, top→bottom: Digital channelC [CH_C], digital channelD [CH_D], USB port, power switch.
2. Screen The display is depicted below: Trigger point Channel Area Display the position of current waveform cache depth Parameter Area Measurement Area Horizontally A—I is channel area; vertically J—T is measurement area. You can move cursor within A—G by scrolling (…); change selection by scrolling (―…+); move cursor between upper & lower menus by pressing (―…+). When cursor is in G Position, press (―…+) to move it within G—I; and press (▲) to move cursor between channel area & measurement area.
FPS Frames Per Second Vpp Peak-to-Peak Voltage Vdc Direct Current Voltage RMS Average Value of Voltage Max Maximum Voltage Min Minimum Voltage FRQ Signal Frequency CIR Signal Cycle DUT Duty factor TH Monocycle High Level Time TL Monocycle Low Level Time Vbt Battery Voltage There are 12 parameters; Short press(●) shows only 8 parameters; Press(●)longer and scroll (―…+)to select parameter, press (―…+) to choose color (channel), press (…)or choose EXT to exit; as below: -------------
E CH_(D)/(A+B)/(A-B)/(C&D)/(C|D)/ REC_A/ REC_B/ REC_C/ REC_D thru CH_D: Input(A+B), waveforms of CH_A & CH_B sync (A-B): get subtraction of waveforms of CH_A & CHA_B (C&D): get and operation of CH_C & CH_D (C|D): get or operation of CH_C & CH_D REC_A: reload the last waveform saved in CH_A Same for REC_B, REC_C & REC_D -AUTO/NORM/ 0.1uS—1S(stepping in 1-2-5 mode) Squ/Sin/Tri/Saw(≈2.
each channel level, press(―… + ) to choose channel(CH_A/CH_B/CH_C/CH_D) Q X Choose the window to display waveforms Scroll(―…+) to choose waveforms of different positions to display on current window R T0 ????? ??????? S 360-4K Memory depth Scroll (―…+) to choose memory depth T EXT/SAV ??????? ???????? --------------------------------------------------------------------------------------------------------------------2.4、Menus On screen, press (■) to access the menu, press again to exit.
menu. Calibrat Instrument calibration (make sure CH_A is ground connected) Press (―…+) to confirm, press (■) to calibrate. IX Application Examples: 1. Example One:Measure simple signals Observe one unknown signal in a circuit, measure & display the frequency & peak-to-peak value of the signal. Please operate according to following steps: Connect the probe of CH_A/CH_B to the detection point of the circuit.
This function can catch occasional incidents very easily; e.g. a sudden sentus of high amplitude. Set the trig level a little higher than normal signal level, press (||), and when the sentus occurs, the device will automatically trig & store the waveforms before & after the trig. It’s depicted as the figure below to better observe the changes of waveforms before & after the trig. 3. Example Three: Cursor measurements A cursor can be used to measure the time and voltage of the waveform very quickly.
Vpp Cycle 4. Example Four: Comparison of Waveforms Module E(REC_A/ REC_B/ REC_C/ REC_D) can be used to compare standard signal & unknown signal. Please operate according to following steps: Input standard signal to CH_A, press (■), choose Save Dat 01 to save waveform, as in Figure 4.1: Input unknown signal to CH_ A, in E position choose REC_A, press (■), choose Load Dat, as Figure 4.2: Move P position Y to adjust horizontal level, to compare waveforms, as in Figure 4.3: Figure 4.
Figure 4.2 Figure 4.3 5. Example Five: Save waveform images Sometimes waveform images need to be archived/analyzed on PC platform. Please operate according to following steps: With prerequisite of correct measurement of signal source, press (■), choose Save Bmp 01, scroll (―…+) to choose file no., press (―…+) to confirm. The file (named IMAG001.BMP) will be saved to built-in USB disk; as in following figure. To analyze waveform images, you only need to copy the images to your PC.
X Operation Tips 1. When measure high frequency signals, to enhance scan speed, it’s suggested to lower buffer depth by adjusting S position, 360 points as a window, and adjust X in Q position to observe the buffer waveforms in the memory. 2. After access to the signal, choose AC coupling scale when need to observe noise and ripple waveform. 3. Use cursor V1 & V2 to measure two random points for voltage difference. 4.
DS203 用户手册 (app_yijian) 目录 一、产品简介………………………………………………………………………………..…….2 二、常规安全概要 ……………………………………………………………………………….. 2 三、主要功能 ……………………………………………………………………………………..2 四、操作注意事项 ………………………………………………………………………………..2 五、一般性检查 …………………………………………………………………………………. 3 六、功能检查 .................................................................................................................................. 3 七、升级固件 …………………………………………………………………………………….3 八、熟悉仪器 …………………………………………………………………………………….
一、产品简介 DS203 是一个 5 踪 4 线的通用电子工程任务的数字示波器。它的基于 ARM Cortex M3 内核的 CPU, 采用 FPGA 实现对外接 ADC 的管理控制和数据缓存,内置 2MB 的 U 盘,用户可以通过 U 盘来存储波形和升 级系统固件,并提供 4 个应用程序分区,方便用户装载和升级最多 4 个不同的应用程序固件。 二、常规安全概要 详细阅读下列安全性预防措施,以避免人身伤害,并防止损坏本产品或与本产品连接的任何产品。 为避免可能的危险,请务必按照规定使用本产品。 避免火灾或人身伤害。 使用合适的电源线。 请只使用本产品专用并经所在国家/地区认证的电源线。 正确连接并正确断开连接。探头或测试导线连接到电压源时请勿插拔,连接电流探头或断开电流探 头的连接之前请将被测电路断电。 遵守所有终端额定值。为避免火灾或电击,请遵守产品上的所有额定值和标记。在对产品进行连接 之前,请首先查阅产品手册,了解有关额定值的详细信息。 请勿在潮湿环境下操作。 请勿在易燃易爆的环境中操作。 请保持产品表面清洁干燥。 三、主要功能 袖珍示波器 DS203 可以帮您验证、调试和表征电子设计。主要功能包括
非工作状态:高温:40 °C 到 60 °C,5 到 60% RH 非工作状态:低温:0 °C 到 40 °C,5 到 90% RH ▌参数 最大瞬时承受电压是 ± 400 V 峰值。 测量电压范围 测量频率范围 逻辑探头输入处的最大输入电压为 ±15 V 峰值。 五、一般性检查 当您得到一台新的 DS203 示波器时,建议您按以下步骤对仪器进行检查。 1.检查是否存在因运输造成的损坏。 如果发现包装纸箱或泡沫塑料保护垫严重破损,请先保留,直到整机和附件通过电 性和机械性测试。 2.检查整机。 如果发现仪器外观破损,仪器工作不正常,或未能通过性能测试,请和公司联系。 如果因运输造成仪器的损坏,请注意保留包装。通知运输部门和负责此业务的 RIGOL 经销商。RIGOL 会安排维修或更换。 六、功能检查 做一次快速功能检查,以核实本仪器运行正常。请按如下步骤进行: 3. 打开电源开关,进入示波器主页面。 4. 示波器接入标准信号(如:方波 20KHz,Vpp=5V), 用示波器探头将信号接入通道 A(CH_A) : 将探头上的开关设定为 1X,并将示波器探头与通道 A 连接。 将探头插槽对准 CHA 插接件上
八、熟悉仪器 1、仪器接口与按键介绍 、正面图,上方有六个按键,从左到右依次是运行/暂停键( || )、菜单键( ■ )、参数键( ● )、 跳转键( ▲ ) 、选项键( ―…+ ) 、移动键(…)。 、左视图,有三个通道,从上到下依次是波形输出[ WAVE OUT ]、模拟通道 B[ CH_B ]、模拟 通道 A[ CH_A ]。 、右视图,从上到下依次是数字通道 C[ CH_C ]、数字通道 D[ CH_D ]、USB 接口、电源开关。 运行/暂停键 菜单键 参数键 选项键 跳转键 移动键 左视图 正面图 右视图 ---------------------------------------------------------------------------------------------------------------------- 2、主屏幕介绍 主屏幕如下图所示: 内存中的 触发位置 通道区 显示当前波形窗口 在内存中的位置 内存缓存 深度 参数区 测量区 19
横向 A—I 选项是通道区,纵向 J—T 是测量区,滚动移动键(…)可使光标在 A—G 之间移动, 滚动选项键( ―…+ )可更改选项,按下选项键( ―…+ )可使光标在上下层菜单跳转,当光标在 G 处时,按下选项键( ―…+ )可使光标在 G—I 之间跳转,按下跳转键( ▲ )可使光标在通道区与测 量区之间跳转,各菜单选项颜色与通道一 一对应,通道 A 菜单(蓝色) 、通道 B(黄色) 、通道 C(紫色)、 通道 D(绿色),公共菜单用橙色。 U—X 是参数区,U 位置是 THR、V1、V2 可选显示的参数,V 位置是参数键首选项显示参数,W 位 置是△T=T2-T1,X 位置是△V=V1-V2 --------------------------------------------------------------------------------------------------------------------2.
--------------------------------------------------------------------------------------------------------------------- 2.2、通道区功能介绍 下表是通道区详细菜单选项功能说明: 菜单 选项 功能(操作:滚动选项键( ―…+ )) A RUN/HOLD (运行状态)运行/暂停,显示电量 B AC/DC/-- (通道 A)交流耦合/直流耦合/隐藏 50mV—10V(1-2-5 步进) 单位小格伏值 AC/DC/-- (通道 B)交流耦合/直流耦合/隐藏 50mV—10V(1-2-5 步进) 单位小格伏值 DC/-- (通道 C)直流耦合/隐藏 -- 无 CH_(D)/(A+B)/(A-B)/(C&D)/(C|D)/ CH_(D):选择通道 D 输入 -- 无 AUTO/NORM/ (触发模式)自动/标准/单次/慢扫描/即时扫 0.1uS—1S(1-2-5 步进) 时间单位值 G Squ/Sin/Tri/Saw(约 2.
菜单 选项 J 功能 操作说明 触发方式:下降沿触发、上 升沿触发、大于触发、小于 触发、负脉宽小于触发、负 脉宽大于触发、正脉宽小于 触发、正脉宽大于触发。 滚动选项键选择触发 方式,按下选项键选择 通道(不同颜色) K THR 触发线: 滚动选项键调节触发 伏值大小(在 U 位置 显示伏值),按下选项 键 选 择 通 道 (CH_A/CH_B/hide) L V1 游标 V1:可视伏值上限 滚动选项键调节伏值 上限大小,按下选项键 选 择 通 道 ( CH_A/CH_B/ CH_C/CH_D/hide) M V2 游标 V2:可视伏值下限 滚动选项键调节伏值 下限大小(在 X 位置 显示 △V=V1-V2),按下选 项 键 选 择 通 道 ( CH_A/CH_B/ CH_C/CH_D/hide) N T1 时间游标 T1 滚动选项键调节时间 游标 T1 大小,按下选 项键选择隐藏游标 T1 O T2 时间游标 T2 滚动选项键调节时间 游标 T2 大小, (在 W 位置显示 △T=T1-T2)按下选项 键选择隐藏游标 T2 P Y 各通道的水平线
2.
设置通道 A(通道 B)为 AUTO 模式,直流耦合(DC) ,调节(水平)时间单位刻度与(竖直)伏值单 位刻度,使信号清晰显示。 调整 THR 值使信号稳定显示。 按下参数键,分析信号参数,例如:Vpp(电压峰峰值)、RMS(平均电压)、FRQ(频率)等。 例如下图: 2、 例二:捕捉单次信号 方便地捕捉脉冲、毛刺等非周期性的信号是数字示波器的优势和特点。若捕捉一个单次信号,首先需 要对此信号有一定的先验知识,才能设置触发电平和触发沿。例如,如果脉冲是一个 TTL 电平的逻辑信 号,触发电平应该设置成 2 伏,触发沿设置成上升沿触发。如果对于信号的情况不确定,可以通过普通 的触发方式先行观察,以确定触发电平和触发沿。 操作步骤如下: 将通道 B 的探头连接到电路被测点。 进行触发设定:J 位置为 (上升沿触发) ,F 位置为 SINGL(单次触发) ,触发设置:直流耦合。 调整水平时基和垂直档位至适合的范围。 调节 K 位置 THR,调整适合的触发电平。 按 RUN/STOP 执行按钮,等待符合触发条件的信号出现。如果有某一信号达到设定的触发电平,即采 样一次,显示在屏幕上。 利用此功能可
3、 例三:应用游标测量 使用游标可迅速地对波形进行时间和电压测量 (1)测量信号源第三个波峰的周期 请按如下步骤操作: 移动光标到 N 位置(T1) 。 滚动选项键将游标 T1 置于信号的第三个峰值处。 移动光标到 N 位置(T2) 。 滚动选项键将游标 T2 置于信号的第四个峰值处。 得到:△T=14.
峰峰值 周期 4、 例四:波形对比 使用 E 位置(REC_A/ REC_B/ REC_C/ REC_D)模块可实现标准信号与未知待测信号对比 请按如下步骤操作: 通道 A 输入标准信号波形,按下菜单键选择 Save Dat 01,保存波形,如下图 4.1。 通道 A 输入未知待测信号,E 位置选择 REC_A,按下菜单键选择 Load Dat,如图 4.2。 移动 P 位置 Y 调节水平线,实现波形对比,如下图 4.
图 4.1 图 4.
图 4.3 5、 例五:保存波形图片 波形图有时需要存档,或是在 PC 机平台分析 请按如下步骤操作: 正确测量信号源前提下,按下菜单键,选中 Save Bmp 01,滚动选项键选择保存图片文件编号,按 下选项键确认,文件将保存在内置 U 盘中,文件名为 IMAG001.
十、操作小技巧 1、当测量高频信号时,为了提高扫描速度,可调节 S 位置降低缓存深度,360 个点为一个窗口,可调 节 Q 位置的 X 选项任意观察内存中缓存得波形。 2、接入信号后,需观察噪声、纹波时,可选择交流耦合档位。 3、可通过游标 V1、游标 V2 测量任意两点电压差值。 4、可通过游标 T1、游标 T2 测量任意两点时间差值。 注:资料如有更新,恕不另行通知 美顺科技 广州胜豪电子科技有限公司 http://shop36212219.taobao.com http://meishun88.taobao.