POWERED BY GOSSEN METRAWATT Operating Instructions 3-447-204-03 1/8.23 Network and LAN Cable Tester KE7200 KE7200 PRO Kit Remote Unit KE7010 KE7010 Kit KE7010 PRO Kit Gossen Metrawatt GmbH | Südwestpark 15 | 90449 Nürnberg Germany Phone +49 911 8602-0 | Telefax +49 911 8602-669 info@gossenmetrawatt.com | www.gossenmetrawatt.
Safety Precautions For proper and safe use, please read and follow these instructions carefully and completely. The instructions must be provided to every user of the instrument. Keep for future reference. General • • • • The instrument may only be used by adequately trained specialists. Observe and comply with all safety regulations applicable for your work environment. Wear suitable and appropriate personal protective equipment (PPE) during all work.
• • Only use the instrument and the accessories in compliance with the specified technical data and under the specified conditions. Do not use the product in potentially explosive atmospheres. Danger of explosion! Batteries • • • Use batteries in undamaged condition only. There is a risk of explosion and fire if the batteries are damaged! Inspect the batteries before use. Pay particular attention to leaky and damaged batteries. Only use the instrument with the battery compartment lid inserted and closed.
Application Please read this important information! Intended/Proper Use The KE7200 is a network and LAN cable tester. It is used for initial startup tests, for checking data and telecommunications networks, and for troubleshooting. The results can be stored in the instrument or transferred to a PC. In the associated PC software, the results can be documented and logs created.
Improper Use Using the instrument for any purposes other than those described in these instrument operating instructions constitutes improper use. Liability and Guarantee Gossen Metrawatt GmbH assumes no liability for property damage, personal injury, or consequential damage resulting from improper or incorrect use of the product, in particular due to failure to observe the product documentation. The same applies to maintenance measures that are not carried out properly or in good time.
Scope of Delivery Please check the scope of delivery for completeness and intactness. KE7200 (D720A) KE7200* network tester and 2 KE7010 remote units 2 × short RJ-45 test cords, 1 × long RJ-45 test cord, 1 × RJ-11 test cord to banana plug, including plug-on crocodile clips, 1 × RJ-45 coax.
Instrument Overview KE7200 Main testing instrument Instrument Overview RJ45 Ethernet test port 10/100/1000 Mbit Attachment for wrist strap Battery status Main Menu Cable test Graphical, backlit display Cable trace Pover over ethernet Network Menu-related operating actions Selection SEL Select KE7200 Ethernet performance tester Return key Select key ESC SEL ON-OFF Navigational UP - DOWN / LEFT - RIGHT keys ON / OFF key Upper edge protector Retractable support bracket Screws for opening/closin
Symbols on the Instrument Warning of a source of danger (please follow documentation!) European conformity marking The instrument must not be disposed of in the household trash; see page 27. KE7010 Remote Unit Active remote unit with microprocessor RJ-45 socket Pass/Fail indication with green LED A maximum of 32 KE7010 units can be managed and used with the KE7200. To identify individual KE7010 units, each remote unit can be assigned an ID from 1 32. The ID can be written down on the back of the KE7010.
Specifications KE7200 Connections RJ-45 socket; Adapter: RJ-45 to coaxial cable, RJ-11 to banana plug, including crocodile clips for banana plug Cable Test (Ethernet cable, coaxial cable, telecommunications cable) Detection of reversed connections, short circuits, interruptions, split pairs (as of 2 m), testing of the data line assignment with pin and pair assignment (wire mapping) Clear graphical display for fast error identification TDR function: Measurement of individual wire lengths from 2 m to 200 m
KE7010 Function Active remote unit with microprocessor Pass/Fail indication with green LED ID freely programmable from 1-32 (at most 32 KE7010 units can be managed and used by the KE7200) Connection RJ-45 socket Housing Stable, impact-resistant ABS housing Dimensions 78 × 45 mm Weight 30 g Power Supply Via RJ-45 Operation Environment Working temperature 0 °C … +50 °C Storage temperature –25 °C … +75 °C Humidity 90%, non-condensing P310 Function Traditional search signal receiver (probe) Feat
Initial Startup KE7200 The instrument is powered by 4× 1.5 V (AA, LR6, alkaline/mignon) batteries (not included with the instrument). Before inserting the batteries, disconnect all test cords and switch off the instrument. Only use batteries according to the specification. The battery compartment is located on the back of the instrument. First loosen the two lower screws of the edge protector (Philips screwdriver required). Remove the edge protector by pulling it downwards. Insert the batteries.
KE7200 Settings All device settings are made in the menu Settings > Instrument Settings. The possible operating steps are displayed in the respective menu in the lower status line. They are preset to empirical values; there is also a Reset to Factory Settings function if something does not work as intended when creating cable or wiring functions. > Language: Either German (default) or English. > Unit of Measure: m (meter) or ft (foot).
Test/Measurement Settings In order to perform all tests/measurements correctly, you need to make basic test settings. In the Settings menu, you can select the Wiring Type for the test/measurement, select the Speed (VF factor) for the TDR function, define the Cable Type, and specify the IP Address of the KE7200.
Settings > Cable Various frequently used cable types are predefined here (for a list, see page 14). The cable to be tested/measured is selected from the list of different cables. The name and the corresponding VF value are assigned to the respective cable type (see page 14). The cable type name appears in the stored or printed result. In contrast, the VF value is needed for the TDR function. You can also add to and change the predefined cable types (see page 14).
Name Pin to pin Wire pair 1 3 568A UTP 1 2 3 4 5 6 7 8 S 2 3 4 5 6 7 8 NC 3 2 1 1 2 4 4 568A UTP CR 1 2 3 4 5 6 7 8 S 3 6 1 7 8 2 4 5 NC 3 3 2 4 4 2 1 1 568B UTP 1 2 3 4 5 6 7 8 S 1 2 3 4 5 6 7 8 NC 568B UTP CR 1 2 3 4 5 6 7 8 S USOC UTP ISDN S BUS Name Pin to pin Wire pair 1 3 568A STP 1 2 3 4 5 6 7 8 S 2 3 4 5 6 7 8 S 3 2 1 1 2 4 4 568A STP CR 1 2 3 4 5 6 7 8 S 3 6 1 7 8 2 4 5 S 3 3 2 4 4 2 1 1 2 2 3 1 1 3 4 4 568B STP 1 2 3 4 5 6 7 8 S 1 2 3 4 5 6 7 8 S 2 2 3 1 1 3 4 4 3 6 1 7 8
TEL 1P UTP PROFINET CR 1 2 3 4 5 6 7 8 S NC NC NC 4 5 NC NC NC NC none none none 1 1 none none none 1 2 3 4 5 6 7 8 S 3 6 1 NC NC 2 NC NC S 1 1 2 none none 2 none none S = shield NC = not connected PROFINET 1 2 3 4 5 6 7 8 S 1 2 3 NC NC 6 NC NC S 1 1 2 none none 2 none none Creating/Changing Wiring Definitions Here, too, you can create your own versions, although you can only do so by changing an existing definition..
> MAC Address The KE7200 is shipped with a predefined MAC address. In order to work in networks with MAC address verification, the address can be freely defined here. Settings > IP Address The IP address of the KE7200 is set here. This address is always used as device address, including for an IP test, such as as static network address. It can be changed at any time. Simply use the ▲ and ▼ / ◄ and ► keys to set the address and save it with SEL.
Test Execution Up to 32 KE7010 remote units can be connected simultaneously to the ports to be measured using the included patch cables. If only one KE7010 is used, it must be taken to the next port after the test has been completed. If an assistant is involved, he can detect whether the test resulted in any errors by the flashing rhythm of the LED after the test has been completed. If no error has been detected (slow flashing every 1 second), he can proceed to the next port.
Storing Data After the measurement has been completed, it can either be exited with ESC, or the Save Data menu can be opened by pressing the SEL key. The predefined name of the measurement – Default – followed by a number is displayed here. If the data is to be assignable later, you will need to enter a unique name here. We recommend customer names or a number. The entry is made by pressing the ▲ or ▼ keys, which allows scrolling through the alphabet and the numbers from 0-9.
PoE/PoE++ Test (according to IEEE802.3af/at/bt) (Ethernet cable only) Connect the KE7200 to the network. Start the test with the SEL key. The KE7200 activates the PoE port and outputs the corresponding information in the display regarding whether PoE/PoE+/ PoE++ is present or not. The PoE standards are displayed according to the expected nominal voltages. PoE/PoE++ Test Higher voltages (fault conditions) can damAlternative A+B age the instrument and pose a potential Line voltage: 57.
• IP of the DHCP server • IP of the router Press the SEL key to save this data. It may happen that not all computers in a network will always respond within the query time of the test device, as they may be occupied with other tasks. This is due to the system-specific nature and does not represent an error. The query can be repeated as often as desired. The subscriber list is opened with ESC.
Data Transmission and Management of Measurements and Log Generation with KE7200 Manager PC Software The KE7200 Manager PC software is a flexible tool for configuring the KE7200 and for downloading test/measurement data from the measuring instrument.
The selection tabs on the top are the same for both displays.
> Load Data (PC) Tests/measurements that have already been saved can be opened for display here (.eth file). > Save All Data Here the data transferred by the KE7200 are selected for saving on the PC (.eth file). > Save Displayed Data Once the data has been selected, it is saved as a separate list (.eth file). > Delete Marked Line This deletes a complete line of test/measurement results. > Print Data A print version (log) of the measurements is created.
Storage and Transport Caution: Improper storage will cause damage to the product. Store the instrument packed and protected from environmental influences. Caution: Improper transport will cause damage to the product. Transport the instrument packed and protected from environmental influences. Only transport the instrument in the supplied bag. Alternatively, we recommend the accessories available for the device (transport case); details can be found on the data sheet.
Contact, Support, and Service Gossen Metrawatt GmbH can be reached directly and simply – we have a single number for everything! Whether you require support or training or have an individual inquiry, we can answer all of your questions here: +49 911 8602-0 Monday to Thursday: 8 a.m. to 4 p.m. Friday: 8 a.m. to 2 p.m. Also available by e-mail: info@gossenmetrawatt.com Do you prefer support by e-mail? Measuring and Test Technology: Industrial Measuring Technology: support@gossenmetrawatt.
Disposal and Environmental Protection Proper disposal makes an important contribution to the protection of our environment and the conservation of natural resources. Caution: Environmental Damage Improper disposal results in environmental damage. Follow the instructions concerning return and disposal included in this section. The following comments refer specifically to the legal situation in the Federal Republic of Germany.
© Gossen Metrawatt GmbH Prepared in Germany • Subject to change, errors excepted All trademarks, registered trademarks, logos, product names, and company names are the property of their respective owners.